Wiring Diagram - Vermont Castings OXDV30NVSB Installation And Operating Instructions Manual

Vermont castings direct vent gas stove
Table of Contents

Advertisement

Oxford Direct Vent / Natural Vent Gas Heater
Wiring Diagrams
On/Off Switch Wiring
TP/TH
TP
TH
Thermostat
Optional Thermostat
(Optional)
Wiring
St124b
on/off/switch
TP/TH
wiring
TP
1/11/00 djt
TH
Fig. 62 On/Off switch and optional thermostat circuit.
NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-
PLIED WITH THE APPLIANCE, MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE SF-2,
200° WIRE OR ITS EQUIVALENT.
St124c
Thermostat
wiring
1/11/00 djt
Safety Limit
Switch
Valve
Fig. 63 Draft hood adapter wiring.
ST665
Safety Limit
Switch wiring
5/29/01 djt
32
ON
OFF
Millivolt
Gas Valve
Black
ST124b
Thermostat
(Optional)
Millivolt
Gas Valve
Black
ST124c
ST665
POWER
CORD
Chassis
GRN
Ground
FAN JUNCTION BOX
Strain Relief
Chassis Ground
MOTOR
ST153
rdv connections diag.
10/99
BLK
ON/OFF
RHEOST AT
Fig. 64 Fan circuit.
ST236
FK26 wiring diagram
12/99
FAN
WHT
BLK
BLK
ON / OFF
Rheostat
Snapstat
WHT
BLK
GRN
RHEOSTAT / SNAPSTAT
BOX
Schematic Diagram
BLK
SNAPST AT
WHT
20306762
ST153
ST236

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents