Oxford Direct Vent / Natural Vent Gas Heater

Install the Optional Fan

If you are installing the optional convection Fan Kit #2767
(FK26), continue here. If you are not installing a Fan Kit,
go to Page 15, Venting System Assembly.
1. The fan kit includes a Blower Assembly and a Rheostat
Assembly, connected by a cable. (Fig. 12) The Blower
Assembly mounts to the bottom rear of the stove, and
the Rheostat mounts to the valve coverplate. The as-
sembly includes a 'snapstat' which automatically turns
the fan On (or Off) above (or below) approximately
109°. The Rheostat also provides a range of fan speed
settings from Off (which overrides the snapstat func-
tion) to High. Unpack and inspect the Blower assem-
bly. Confirm that the fan spins freely.
WARNING
This appliance is equipped with a three-prong (ground-
ed) plug for your protection against shock hazard and
should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the
grounding prong from this plug.
Not Used on RF
Models
Not Used
on
Oxford
Blower
Assembly
ST473
Fig. 12 Fan kit components.
2. Remove the rear skirt insert panel at the bottom of the
ST473
Rear Skirt (Fig. 13) and fasten the blower assembly to
Fan parts
the firebox back with the two Phillips pan-head bolts
#2767 FK26
originally installed in the firebox back. ('1', Fig. 14)
9/29/00
3. Attach the snapstat assembly to the snapstat bracket
with two sheet-metal screws. ('2', Fig. 14) Attach the
snapstat bracket to the stove with a hex-head bolt
passing through the bracket and into the stove base.
('3', Fig. 14)
4. The rheostat control switch attaches to the left side of
the valve bracket at the front of the stove.
14
Snapstat
Bracket
Snapstat/
Extension
Assembly
Rheostat
Assembly
Not Used
on RF
Models
Connect to PC Board on
RF Models Only
Remove retaining nut from shaft of rheostat. (if pre-
installed)
Insert the rheostat through the hole in the back of
the left side of the valve bracket, aligning the locator
pin with the smaller hole in that bracket.
Thread the retaining nut onto the shaft of the rheo-
stat, tightening with a wrench. Do not overtighten.
Attach the control knob to the rheostat shaft.
Use the wire tie to secure the fan and rheostat wire
harnesses together.
Rear Skirt
Sheet Metal
Screws
Rear Skirt Insert
Fig. 13 Remove rear skirt insert.
Star Washer
Sheet Metal Screws
2
Phillips
1
Pan Head
Bolts
Star
Washer
Fig. 14 Attach the fan assembly and the snapstat.
ST314
Fk26ce
attach fan
1/24/00
Rheostat
Retaining Collar
Rheostat Knob
Fig. 15 Attach the fan rheostat.
ST757
ST1123
rear skirt insert
Snapstat
1/4" - 20
Hex Bolt
Snapstat
Bracket
3
ST758
Dutchwest
20306762
attach rheostat
5/15/03 djt
ST314
ST758