Install Vent Adapter Pipe (Dura-Vent Components); Side Wall Termination Assembly - Vermont Castings OXDV30NVSB Installation And Operating Instructions Manual

Vermont castings direct vent gas stove
Table of Contents

Advertisement

Oxford Direct Vent / Natural Vent Gas Heater
Install the Vent Adapter Pipe
(Simpson Dura-Vent Components)
1. Install the Restrictor Plate. Consult Page 9 to deter-
mine whether the restrictor plate is needed. If so, place
the restrictor plate into the inner flue collar. (Fig. 16)
2. Discard the inner starter pipe shipped with the log-
set. Using the starter pipe assembly listed on Page 7,
slide the inner section out to allow access.
• Run a bead of sealant around the bottom end of the
starter pipe and attach the assembly to the stove using
three 1/4-20 x 3/8" Phillips screws provided in the parts
bag. (Fig. 20)
3. Install the Outer Adapter Pipe. Apply a 1/4" bead of
cement around the outside surface, about one inch
from the crimped end. (Fig. 21) Orient the vertical
seam to the rear, and insert the crimped end of the
outer pipe into the flue collar. Fasten with three sheet
metal screws provided.
1/4-20 x 3/8
Phillips Screws
Fig. 20 Simpson DuraVent - install inner adapter pipe.
ST762
dura vent
attach inner assy
Fig. 21 Simpson DuraVent - install outer adapter pipe.
5/15/03 djt
16
ST763
DW dura vent
attach outer assy
1. Locate the vent opening on the wall. Refer to Figure 5,
Page 7, to determine the opening centerline. It may be
necessary to first position the stove and measure to
find the hole location. Depending on whether the wall
is made of combustible materials, cut the opening to
the size shown in Figure 22. Combustible wall open-
ings must be framed as shown in Figure 22.
Vermont Castings Group System
DuraVent
System
Inner Adapter
Pipe
Fig. 22 Locate vent opening.
2. Measure the wall thickness and cut the wall sleeve
sections to proper length (MAXIMUM 12"). Assemble
the sleeve with the #8 sheet metal screws supplied. At-
tach the firestop plate to the sleeve end with the holes.
(Fig. 23) NOTE: The wall sleeve is required in com-
bustible walls only.
3. Install the Wall Firestop/Sleeve assembly into the wall
ST762
cutout and fasten the firestop to the wall cutout framing
members. (Fig. 23)
ST763
Fig. 23 Assemble the wall sleeve and firestop.

Side Wall Termination Assembly

9
"
3
8
(240 mm
9
"
3
8
(240 mm
Combustible Wall
10"
(250 mm)
10"
(250 mm)
VO584-100
Vent Opening
2/99 djt
12"
(305 mm)
Max. Length
Firestop
ZCS103
Zero Clearance Sleeve
& Firestop
12/6/99 djt
Framing Detail
7
"
1
2
(191 mm)
VO584-100
Sleeve
ZCS103
20306762

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents