INSTALLER / CONSUMER

SAFETY INFORMATION

Please read this manual before
installing and using appliance.
WARNING: If the information in
this manual is not followed ex-
actly, a fire or explosion may
result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency or the gas suppler.
WHAT TO DO IF YOU SMELL GAS
• Shut off the gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas
supplier, call the fire department.
Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or
any other appliance.
WARNING:
Improper installa-
tion, adjustment, alteration,
service or maintenance can cause
injury or property damage. Refer
to this manual for correct installa-
tion and operational procedures.
For assistance or additional infor-
mation consult a qualified
installer, service agency, or the
gas supplier.
This is an unvented gas-fired heater. It
uses air (Oxygen) from the room
which it is installed. Provisions for
adequate combustion and ventilation
air must be provided.
Installation and service must be
performed by a qualified in-
staller, service agency or the gas
supplier.
Radiance
Vent Free Gas Heater
Model RUVS40
Homeowner's Installation
and Operating Manual
ANSI Z21.11.2b-1998, Unvented Heaters
INSTALLER: DO NOT DISCARD THIS MANUAL -
LEAVE FOR HOMEOWNER
Vermont Castings Radiance
Tested and listed to
0456
3000-0456c/1000
1

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings Radiance RUVS40

  • Page 1: Safety Information

    Vermont Castings Radiance Radiance Vent Free Gas Heater Model RUVS40 Homeowner’s Installation and Operating Manual Tested and listed to ANSI Z21.11.2b-1998, Unvented Heaters INSTALLER: DO NOT DISCARD THIS MANUAL -...
  • Page 2: Table Of Contents

    Vermont Castings Radiance ATTENTION CONSUMER: In order to ensure safe and effective installation, this unit must be installed only by a qualified agency, individual, firm, corporation, or company that is experienced in the installation, repair and servicing of this type of appliance and is familiar with the building codes and installation techniques appropriate in your area.
  • Page 3: Specifications

    Specifications Radiance Unvented Gas Heater RUVS40 Fuel Type: Manifold Pressure; Min. / Max.: 1.7"/3.5" 5.4"/11.0" Min. Inlet Supply Pressure for adjustment:: 5.0" W.C. 11.0" W.C. Max. Inlet Supply Pressure for adjustment: 8.0" W.C. 12.0" W.C. Min. Output, BTU/hr: Max. Output, BTU/hr:...
  • Page 4: Safety Information

    Vermont Castings Radiance Safety Information IMPORTANT: Read this owner's manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. CARBON MONOXIDE POISONING MAY LEAD TO DEATH! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea.
  • Page 5: General Information

    General Information Vent Free Features The Radiance RUVS40 is an unvented gas heating appliance tested and listed to the ANSI standard Z21.11.2a 1997. This appliance is specifically configured to burn either Natural Gas or Propane fuel, as indicated on the metal rating plate attached to the rear shroud. The Radiance RUVS40 is not fuel convertible.
  • Page 6: Installation Requirements

    Vermont Castings Radiance Installation Requirements WARNING THIS HEATER MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT, POOR FUEL COMBUSTION COULD RESULT. READ THE FOLLOWING INSTRUCTIONS TO INSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL-BURNING APPLIANCES IN YOUR HOME. Fresh Air Requirements for Combustion and Ventilation Modern construction standards have resulted in homes...
  • Page 7 3. Add the BTU/Hr ratings of all fuel-burning appli- ances installed in the same space, including the following: Gas Water Heater Gas Furnace Gas Fireplace Logs Unvented Gas Heater Vented Gas Heater* Other Gas Appliances* * Do not include Direct Vent appliances as these utilize outside air for combustion and vent to the outdoors.
  • Page 8: Clearance Requirements

    Vermont Castings Radiance Clearance Requirements Minimum Clearances to Combustible Materials Maintain clearance, (empty space), between combus- tible materials and the heater as specified below. Freestanding Stove A: Maximum Mantel Depth ... 7 " (190.5mm) B: To Side Wall / Trim* ... 4" (101.6mm) C: To Rear Wall ...
  • Page 9: Assembly

    Assembly Read these instructions thoroughly before starting the assembly. Follow procedures in the order given. Inspect the stove for damage before starting the assembly. Do not install this stove if any damage is evident. Contact your dealer immedi- ately. The Radiance is shipped on its back, mounted to a wooden pallet.
  • Page 10 109 F. The rheostat provides a range of fan speed settings from OFF (which overrides the snapstat function) to high. Kit Contents used with the RUVS40: • Fan assembly with rheostat and snapstat • wire tie • control knob • retaining collar These directions are oriented facing the rear of the stove.
  • Page 11 5. Resecure the Rear Shroud panels. • Reinstall and tighten the two sheet metal screws (D, Fig. 10) that secure the inner and outer shrouds together. • Secure the upper corner of the shroud and switch box to the side of the stove using a 1/4 -20 x 1/2” round head phillips screw, previously removed.
  • Page 12 Vermont Castings Radiance Thermostat Connection Use only a millivolt rated thermostat. Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation. Thermostat Wire Gauge / Maximum Run 1. Install the wall thermostat in the desired location and run the wires to the stove location.
  • Page 13 Fig. 17 Remove the valve cover plate. Fig. 18 Flexible gas line connection. On/Off Pilot Control Adjustment Knob Screw Piezo Pressure Tap Ignitor Fig. 19 The gas control valve includes a captured screw- type pressure test point. A pressure test point upstream from the control valve is not required.
  • Page 14: Complete The Installation

    4. Set the screen and the cast-iron grate into the recess in the stove top. This completes the installation and assembly of the Radiance RUVS40. Fig. 24 Replace the front panel. ST145a Fig. 25 Attach the handle to the control door.
  • Page 15: Operation

    Figures 26 - 30 illustrate the operating positions for the RUVS40 controls. Set the 3-way burner control switch on the back of the appliance to the OFF position (midpoint). Locate the Pilot assembly on the right side behind the burener.
  • Page 16: For Your Safety Read Before Lighting

    Vermont Castings Radiance FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot. When lighting the pilot, follow these instructions exactly. B.
  • Page 17 Trouble- Condition No spark at Pilot when Ignitor is operated The Iignitor Electrode sparks, but Pilot does not light Pilot lights but flame goes out when Contorl Knob is released. Warning Turn OFF heater and allow to cool completely before servicing. Possible Cause 1.Ignition Electrode is disconnected from ignition wire, broken o incor-...
  • Page 18: Troubleshooting

    2.Foreign material is blocking Burner ports. 3.Main Burner orifice is clogged. 4.Thermostat or remote switch not activated on RUVS40. 1.Insufficient fresh air. 2.Incorrect inlet supply pressure. Odor During Operation Neither natural gas nor LP gas give off an odor when burned.
  • Page 19: Maintenance

    Maintenance Your Radiance Vent Free heater will provide years of service with minimal upkeep. The following procedures will help ensure that your heater continues to perform safely and efficiently. Firebox Cleaning and Inspection Cleanliness is critical to correct operation of the heater.
  • Page 20: Catalytic Combustor

    Vermont Castings Radiance Catalytic Combustor The combustor should be cleaned annually to ensure optimal performance. Follow the procedure below. Tools / Materials: • phillips screwdriver • rubber gloves • baking soda • tap water • white vinegar • distilled water Remove the combustor module 1.
  • Page 21: Parts List

    The Vermont Castings, Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Radiance Vent Free Gas Heater RUVS40 Item/Model Number 1. Grille 2. Grille Screen 3.
  • Page 22 Sheet Metal Screw (39) 1601930 60. 8-32 x 2" Rnd Hd Slotted Screw(1) 1409110 61. #10-24 X 1/4" Phil. Pn Hd Screw (4) 10000235 1000-0242 THERMOSTAT (OPTIONAL) Fig. 37 RUVS40 Wiring Diagram Part Number 20000101 20000851 30000448 1301148 30000328 1409136 1301229...
  • Page 23 Warranty Limited Three Year Warranty The Vermont Castings, Majestic Products Comany warrants that this Radiance Natural Vent Room Heater will be free of defects in material and workmanship for a period of three years from the date you receive it, except that the glass door panel, ceramic logs, and gasketing shall be warranted for one year as described below.
  • Page 24 Vermont Castings Radiance The Vermont Castings, Majestic Products Company 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7885 www.majesticproducts.com • www.vermontcastings.com © The Vermont Castings, Majestic Products Company...

Table of Contents