Your First Fire

Read these instructions carefully and familiarize yourself
with the burner controls. Locate the pilot assembly, Figure
46. Follow the lighting instructions on Page 25 exactly.
During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being heated.
Odors should dissipate within an hour or so, however, you
can open a window to provide fresh air to alleviate the
condition.
Pilot and Burner Inspection
Each time you light your heater check that the pilot flame
and burner flame patterns are as shown in Figure 48. If
flame patterns are incorrect, turn the heater off. Contact
your dealer or a qualified gas technician for assistance.
Do not operate the heater until the pilot flame is correct.
Follow regular maintenance procedures as described on
Page 30.
Pilot Assembly
Fig. 46 Pilot assembly location.
ST769
Dutchwest
pilot location
5/15/03 djt
20306762
Oxford Direct Vent / Natural Vent Gas Heater

Operation

Flame & Temperature Adjustment
For stoves equipped with HI/LO valves, flame adjustment
is accomplished by rotating the HI/LO adjustment knob
located near the center of the gas control valve. (Fig. 47)
Turn
counterclockwise
to decrease
flame height
Fig. 47 Flame adjustment knob for Honeywell valve.
It is important to periodically perform a visual check of
the pilot and the burner flames. Compare them to Figure
47. If any of the flames appear abnormal, call a service
person.
ST769
Red
Glow
Fig. 48 Correct pilot and burner flame patterns.