Vermont Castings OXDV30NVSB Installation And Operating Instructions Manual

Vermont Castings OXDV30NVSB Installation And Operating Instructions Manual

Vermont castings direct vent gas stove
Table of Contents

Advertisement

Direct Vent Gas Stove
Installation and Operating Instructions
Models: OXDV30NVSB
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do
not use any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
– If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information consult
a qualified installer, service agency or the
gas supplier.
This appliance is for use only with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certified kit is used.
This appliance may be installed in an aftermarket,*
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
DANGER
5123
Oxford cover
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall
be installed for the protection of children and
other at risk individuals.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
CERTIFIED
S
B
AFETY
ARRIER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
20306543
20306762 12/14 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings OXDV30NVSB

  • Page 1 Direct Vent Gas Stove Installation and Operating Instructions CERTIFIED Models: OXDV30NVSB AFETY ARRIER WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    Venting System Assembly - Direct Vent ....15 Install Vent Adapter Pipe (Vermont Castings Group Vent Components) ..15 Install Vent Adapter Pipe (Dura-Vent Components) ..16 Side Wall Termination Assembly .
  • Page 3: General Information

    Oxford Direct Vent / Natural Vent Gas Heater General Information The Oxford Direct Vent/Natural Vent Room Heater, Model WARNING: Operation of this heater when not connected No. OXDV30NV, is a vented gas appliance listed to the ANSI to a properly installed and maintained venting system standard Z21.88-2009 and CSA-2.33-2009 for Vented Room can result in carbon monoxide (CO) poisoning and pos- Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use...
  • Page 4: Requirements For The Commonwealth Of Massachusetts

    Oxford Direct Vent / Natural Vent Gas Heater Requirements for the Commonwealth of Massachusetts Exemptions All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber. The following equipment is exempt from 248 CMR For all side wall horizontally vented gas fueled equipment 5.08(2)(a)1 through 4: installed in every dwelling, building or structure used in whole...
  • Page 5: Oxford Dimensions

    Oxford Direct Vent / Natural Vent Gas Heater Oxford Direct Vent / Natural Vent Dimensions Refer to Page 6 for Flue Collar Centerline Dimensions 6³⁄₄" (172mm) Valve Inlet 24¹⁄₂" (622mm) 28³⁄₈" (721mm) C L Valve 4³⁄₈" Inlet (111mm) 12¹⁄₂" 23" (318mm) (584mm) 17"...
  • Page 6: Installation Requirements

    Oxford Direct Vent / Natural Vent Gas Heater Installation Requirements The installation must conform with local codes or, in the Direct Vent System Only absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do not derate this appliance for altitude.
  • Page 7: Parallel Installation

    ⁄ " (395 mm) Effective Minimum ST128c D: 9" (229 mm) ST128b Wall Thimble ⁄ " (1461 mm) (Vermont Castings Group Fig. 3 Parallel installation, minimum back and side clearances Stardance Pipe) ST1121 and flue centerlines. Centerline ⁄ " (1359 mm) (Simpson DuraVent Pipe)
  • Page 8: Gas Specifications

    Oxford Direct Vent / Natural Vent Gas Heater Horizontal Termination - Gas Specifications Direct Vent ONLY Max. Min. Input Input The vent must rise vertically a minimum of 24” (610 mm) Model Fuel Gas Control BTU/h BTU/h off the top of the unit, before the first elbow. The horizontal 2465 Millivolt 28,000...
  • Page 9: Vertical Termination - Direct Vent Only

    Oxford Direct Vent / Natural Vent Gas Heater Vent Termination Clearances Vertical Termination - Direct Vent ONLY When planning the installation, consider the location of A vertical vent system must terminate no less than 8' (2.44 m) and no more than 40' (12 m) above the appli- the vent terminal and clearances.
  • Page 10 Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termina- • Only Vermont Castings Group and Duravent vent- tion area after snow falls, and clear to prevent accidental ing components specifically approved and labelled blockage of venting system.
  • Page 11: General Venting Information - Termination Location

    2. The special venting system used on Direct Vent appliances are certified as part of the appliance, with clearances tested and approved by the listing agency. 3.Vermont Castings Group assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.
  • Page 12: Termination Clearances

    Oxford Direct Vent / Natural Vent Gas Heater Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony - Balcony - with no side wall...
  • Page 13: Venting Requirements And Options - Direct Vent Only

    These parts are available from DuraVent Cor- Vertical Termination Kit, 7/12-12/12 Pitch 7TDVSKVB poration or your Vermont Castings Group Dealer. (1) 7/12 - 12/12 Flashing Refer to Figure 4 for dimensions relevant to the standard mini- and all of the other Vertical Termination parts.
  • Page 14: Install The Optional Fan

    Oxford Direct Vent / Natural Vent Gas Heater • Remove retaining nut from shaft of rheostat. (if pre- Install the Optional Fan installed) If you are installing the optional convection Fan Kit #2767 • Insert the rheostat through the hole in the back of (FK26), continue here.
  • Page 15: Venting System Assembly - Direct Vent

    First Section of Vent Pipe Install the Vent Adapter Pipe #8 x 1/2” Sheet (Vermont Castings Group Vent Components) Metal Screws 1. Install the Restrictor Plate. Consult the ‘Vent Run Specifications’ on Page 8 to determine whether the restrictor plate is needed. If so, put the restrictor plate 4”...
  • Page 16: Install Vent Adapter Pipe (Dura-Vent Components)

    Figure 22. slide the inner section out to allow access. • Run a bead of sealant around the bottom end of the Vermont Castings Group System starter pipe and attach the assembly to the stove using ⁄...
  • Page 17 Fasten wall plate to wall. 4. For Vermont Castings Group Vent Pipe only: If nec- essary, measure to determine the vertical length (X) of pipe required from the adapter pipe to the wall cutout ST215 centerline, including a 2”...
  • Page 18: Vent Termination Below Grade

    Firestop 2. Plumb to the center of the inner (4”) flue collar from the ceiling above, and mark that location. 3. Cut the opening: 4” Clearance Vermont Castings Group System: ⁄ " x 9 ⁄ " (240 x 240 mm) Gravel DuraVent System: 10"...
  • Page 19: Venting System Assembly - Natural Vent

    The heater is approved for installation as a Natural Vent. overall height. Vermont Castings Group Direct Vent pipe could be used 11. Apply cement to the inner and outer termination col- directly after the Draft Hood Adapter up to the ceiling, lars and install the terminal cap.
  • Page 20: Install The Log Set

    Oxford Direct Vent / Natural Vent Gas Heater Attach the first section of venting to the draft hood. De- Left Log pending on the length of the individual venting sections Right Log and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sec- tions before attaching upper sections to lower ones.
  • Page 21: Burner Information

    Oxford Direct Vent / Natural Vent Gas Heater In the U.S.; Gas connection should be made in accor- To adjust the air shutter, the following procedures should dance with current National Fuel Gas Code, ANSI Z223.1/ be followed: NFPA 54. Since some municipalities have additional local 1.
  • Page 22: Complete The Assembly

    Oxford Direct Vent / Natural Vent Gas Heater shutter in place. The shutter may be adjusted between the factory adjusted 1/2” to fully open. Reassemble the shutter to allow the rear injector air inlet to close from Left Burner Leg the minimum 1/2”...
  • Page 23: Thermostat Connection (Optional)

    Oxford Direct Vent / Natural Vent Gas Heater Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge thermo- stat wire to use for the length of lead required in your in- stallation.
  • Page 24: Safety Barrier Installation

    Oxford Direct Vent / Natural Vent Gas Heater DANGER CERTIFIED AFETY ARRIER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS Safety Barrier Installation Instructions UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. NOTE: A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this A barrier designed to reduce the risk of burns from the hot appliance and shall be installed for the protection of...
  • Page 25: Operation

    Oxford Direct Vent / Natural Vent Gas Heater Operation Your First Fire Flame & Temperature Adjustment Read these instructions carefully and familiarize yourself For stoves equipped with HI/LO valves, flame adjustment with the burner controls. Locate the pilot assembly, Figure is accomplished by rotating the HI/LO adjustment knob 46.
  • Page 26: Lighting And Operating Instructions

    Oxford Direct Vent / Natural Vent Gas Heater Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 27: Troubleshooting - Sit Nova 820 Gas Control System

    Oxford Direct Vent / Natural Vent Gas Heater Troubleshooting the Gas Control System SIT NOVA 820 MILLIVOLT VALVE NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. Possible Causes Corrective Action Symptom 1.
  • Page 28: Fuel Conversion Instructions

    Oxford Direct Vent / Natural Vent Gas Heater Fuel Conversion Instructions WARNING! This conversion kit shall be installed Remove Screws Rear Log Bracket by a qualified service agency in accordance with Pilot the manufacturer’s instructions and all applicable codes and requirements of the authority having ju- risdiction.
  • Page 29 Oxford Direct Vent / Natural Vent Gas Heater Pilot Orifice Conversion 1. Locate pilot. (Fig. 50) 2. Replace pilot orifice. Pilot Pilot Type 1 • Remove pilot hood by lifting up. (Fig. 53) Do not re- move snap ring to remove pilot hood. NOTE: It is not Index necessary to remove the pilot tube for conversion.
  • Page 30: Annual System Inspection

    Oxford Direct Vent / Natural Vent Gas Heater Table 2. Injector Orifice Size Matrix Conversion to Natural Gas Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maximum 30005155 #54 / .055" 30000514 #44 / .086” 30000334 19,000 28,000 Conversion to LP Input (BTU/h)
  • Page 31: Glass Replacement

    Oxford Direct Vent / Natural Vent Gas Heater Glass Replacement Inspect the Vent System Annually Replace glass only with Vermont Castings Group ap- Have the vent system inspected annually by a qualified proved parts. Refer to Page 33 for Replacement Parts.
  • Page 32: Wiring Diagram

    Oxford Direct Vent / Natural Vent Gas Heater Wiring Diagrams POWER On/Off Switch Wiring CORD Chassis TP/TH Ground Millivolt Gas Valve Black ST124b Thermostat Optional Thermostat FAN JUNCTION BOX (Optional) Thermostat (Optional) Wiring Strain Relief St124b ON / OFF on/off/switch TP/TH Rheostat wiring...
  • Page 33: Replacement Parts

    Oxford Direct Vent / Natural Vent Gas Heater Replacement Parts 36a,b 15a,b, Vermont Castings Group reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Ref. Description Oxford Gas Log Assembly - SDV30...
  • Page 34 Oxford Direct Vent / Natural Vent Gas Heater Replacement Parts (continued) Ref. Description Oxford Glass, DV25 1601691 Glass Frame Assembly - SDV30 30000127 Gasket, Glass - Med. Knit - RDV40 1203702 Pilot Top Convertible 10002266 Pilot Assembly 3Way N/DV RN 0.199.706 10002264 Pilot Assembly 3Way N/DV RP 0.199.703 10002265...
  • Page 35: Optional Accessories

    Oxford Direct Vent / Natural Vent Gas Heater Optional Accessories Fan Kits Remote Controls FK26 Fan The remote control allows you to turn the heater on or off from anywhere in the room. Refer to Page 32 for wiring The FK26 fan helps distribute heated air from within diagrams.
  • Page 36 Oxford Direct Vent / Natural Vent Gas Heater 20306762...
  • Page 37 Oxford Direct Vent / Natural Vent Gas Heater 20306762...
  • Page 38 Oxford Direct Vent / Natural Vent Gas Heater 20306762...
  • Page 39: Limited Lifetime Warranty

    Oxford Direct Vent / Natural Vent Gas Heater LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings Group gas stoves equipped with an Insta-Flame Ceramic Burner. BASIC WARRANTY Vermont Castings Group (hereinafter referred to collectively as the • Any part and/or component replaced under the provisions of this war-...
  • Page 40 EFFICIENCY RATINGS EnerGuide Ratings Fire- Model place Efficiency (%) OXDV30NV 63.0 Based on CSA P.4.1-09 Recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz Énerguide Based on CSA P.4.1-09 Selon CSA P.4.1-09 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.com...