Symbol LT 1806 Product Reference Manual page 31

Keyboard wedge/synapse
Hide thumbs Also See for LT 1806:
Table of Contents

Advertisement

LT 1806 Product Reference Guide: Programming the LT 1806
Beeper Definitions
Standard Use
BEEPER SEQUENCE
1 Beep - short high tone
2 Beeps - long high tone
3 Beeps - short high tone
Parameter Menu Scanning
BEEPER SEQUENCE
1 Beep - short high tone
1 Beep - warble sound
2 Beeps - long low tone
Code 39 Scan and Store
BEEPER SEQUENCE
1 Beep - hi/low tone
1 Beep - short lo/hi/lo tone
3 Beeps - long high tone
4 Beeps - long low tone
1 Beep - lo/hi tone
INDICATION
A symbol has been successfully decoded.
Data transmission not successful.
Power-up, or watchdog reset.
INDICATION
Successful entry of a bar code in a
programming sequence.
Parameter value has been entered
successfully.
Incorrect programming sequence
performed. Scan CANCEL and try
program sequence again.
INDICATION
Indicates new data being entered into the
buffer.
The buffer has been erased, or there was an
attempt to transmit an empty buffer.
Code 39 buffer is full.
Error in transmitting stored buffer data.
Transmission of stored buffer data is good.
4-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents