Quick Test" Mode For Eoc Iii - Jenn-Air JDS8850BD Service Manual

Dual fuel slide-in range
Hide thumbs Also See for JDS8850BD:
Table of Contents

Advertisement

Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.

"Quick Test" Mode for EOC III

Follow the procedure below to perform the EOC III quick test. Once the control is in the quick test mode, any relay
may be activated in any sequence. The test mode will be exited after 10 minutes of inactivity (no pads pressed
within 10 minutes).
1. Press the Setup pad, then press the right ATM pad.
2. Press the left ATM pad, then press and hold Back and Enter pads for 5 seconds to enter SERVICE menu options.
3. Press the right ATM pad to scroll to the TEST menu.
4. Press the left ATM pad to select TEST options.
5. Press the left ATM pad again to enter the "Quick Test" mode.
6. Press each of the following pads indicated in the table below.
7. Press Cancel or Setup pads to exit.
Press and hold the applicable pad to activate the associated response.
NOTE:
Release the applicable pad to deactivate the associated response.
The control automatically enters the engineering mode so visual feedback of relay operations is available on the
control display. Any time a load is activated, the cooling fan is activated. When the load is deactivated, the cooling
fan is also deactivated.
Display will indicate the following:
Pad
BAKE....................................................Bake relay activated.
BROIL ..................................................Broil relay activated.
CONVECT ...........................................Convection Bake relay activated.
OVEN LIGHT .......................................Oven light relay activated.
RAPID PREHEAT ................................Convection Fan (HIGH/LOW) activated.
WARMING ZONE ................................Warming Zone relay activated.
VENT (DOWNDRAFT) FAN ................Vent Fan relay activated.
CLEAN .................................................Motorized Door Lock relay activated.
SETUP .................................................1 Second Beep.
FAN ......................................................Downdraft Fan (HIGH/LOW) relay activated.
WARMING DRAWER ..........................Warming Drawer (HIGH/LOW) relay activated.