MASTER  PROGRAMMING  MODE  
continued
12.
Press  the  Extra  Cycle  button.  Use  this  display  to  set  the  
control  will  initiate  a  delayed,  manually  queued,  or  day  override  
in  the  upper  left  hand  corner  of  the  screen.  Use  the  Up  and  
Down  buttons  to  adjust  the  value  as  needed.
13.
Press  the  Extra  Cycle  button.  Use  this  display  to  set  the  
Regeneration  Cycle  Step  Times.  The  different  regeneration  
cycles  are  listed  in  sequence  based  on  the  valve  type  selected  
upper  left-­hand  corner  of  the  screen.  The  abbreviations  used  
as  R1,  R2,  R3,  R4,  R5,  and  R6.  Each  cycle  step  time  can  be  
set  from  0  to  199  minutes.  Setting  a  cycle  step  time  to  0  will  
cause  the  control  to  skip  that  step  during  regeneration,  but  
keeps  the  following  steps  available.  Use  the  Up  and  Down  
buttons  to  adjust  the  value  as  needed.  Press  the  Extra  Cycle  
button  to  accept  the  current  setting  and  move  to  the  next  
parameter.
Cycle  Step
B1
Backwash
BD
Brine  Draw
B2
Backwash
RR
Rapid  Rinse
BF
Brine  Fill
SV
Service
Range:  0-­199  minutes
14.
Press  the  Extra  Cycle  button.  Use  this  display  to  set  the  
D1,  D2,  D3,  D4,  D5,  D6,  and  D7  in  the  upper  left-­hand  corner  
of  the  display.  Set  the  value  to  "ON"  to  schedule  a  regeneration  
or  "OFF"  to  skip  regeneration  for  each  day.  Use  the  Up  and  
Down  buttons  to  adjust  the  setting  as  needed.  Press  the  Extra  
Cycle  button  to  accept  the  setting  and  move  to  the  next  day.  
Note  that  the  control  requires  at  least  one  day  to  be  set  to  
"ON."  If  all  7  days  are  set  to  "OFF",  the  unit  will  return  to  Day  
One  until  one  or  more  days  are  set  to  "ON."
15.
Press  the  Extra  Cycle  button.  Use  this  display  to  set  the  current  
corner  of  the  screen.  Use  the  Up  and  Down  buttons  to  select  
from  Day  1  through  Day  7.
16.
Press  the  Extra  Cycle  button.  Use  this  display  to  set  the  type  
Use  the  Up  and  Down  buttons  to  select  one  of  the  7  available  
settings.
GEn
t1.2
17.
Press  the  Extra  Cycle  button.  Use  this  display  to  specify  the  
the  screen.  Use  the  Up  and  Down  buttons  to  enter  the  meter  
constant  in  pulses  per  unit  volume.
Range:  1-­999.9
18.
Press  the  Extra  Cycle  button  to  save  all  settings  and  exit  
Master  Programming  Mode.
Generic/Other  Meter
7000  Meter