MASTER PROGRAMMING MODE
continued
12.
Press the Extra Cycle button. Use this display to set the
control will initiate a delayed, manually queued, or day override
in the upper left hand corner of the screen. Use the Up and
Down buttons to adjust the value as needed.
13.
Press the Extra Cycle button. Use this display to set the
Regeneration Cycle Step Times. The different regeneration
cycles are listed in sequence based on the valve type selected
upper left-hand corner of the screen. The abbreviations used
as R1, R2, R3, R4, R5, and R6. Each cycle step time can be
set from 0 to 199 minutes. Setting a cycle step time to 0 will
cause the control to skip that step during regeneration, but
keeps the following steps available. Use the Up and Down
buttons to adjust the value as needed. Press the Extra Cycle
button to accept the current setting and move to the next
parameter.
Cycle Step
B1
Backwash
BD
Brine Draw
B2
Backwash
RR
Rapid Rinse
BF
Brine Fill
SV
Service
Range: 0-199 minutes
14.
Press the Extra Cycle button. Use this display to set the
D1, D2, D3, D4, D5, D6, and D7 in the upper left-hand corner
of the display. Set the value to "ON" to schedule a regeneration
or "OFF" to skip regeneration for each day. Use the Up and
Down buttons to adjust the setting as needed. Press the Extra
Cycle button to accept the setting and move to the next day.
Note that the control requires at least one day to be set to
"ON." If all 7 days are set to "OFF", the unit will return to Day
One until one or more days are set to "ON."
15.
Press the Extra Cycle button. Use this display to set the current
corner of the screen. Use the Up and Down buttons to select
from Day 1 through Day 7.
16.
Press the Extra Cycle button. Use this display to set the type
Use the Up and Down buttons to select one of the 7 available
settings.
GEn
t1.2
17.
Press the Extra Cycle button. Use this display to specify the
the screen. Use the Up and Down buttons to enter the meter
constant in pulses per unit volume.
Range: 1-999.9
18.
Press the Extra Cycle button to save all settings and exit
Master Programming Mode.
Generic/Other Meter
7000 Meter