Error Type
0
Cam Sense
The valve drive took longer than
Error
6 minutes to advance to the next
1
Cycle Step
The control experienced an
Error
2
Regen
The system has not regenerated
Failure
for more than 99 days (or 7 days
if the Control Type has been set to
3
Memory
Control board memory failure
Error
continued
regeneration position
unexpected cycle input
Day-of-Week)
Unplug the unit and examine the powerhead. Verify that all cam switches are
connected to the circuit board and functioning properly. Verify that the motor
and drive train components are in good condition and assembled properly.
Check the valve and verify that the piston travels freely. Replace/reassemble
the various components as necessary.
Plug the unit back in and observe its behavior. The unit should cycle to
the next valve position and stop. If the error re-occurs, unplug the unit and
contact technical support.
Unplug the unit and examine the powerhead. Verify that all cam switches
are connected to the circuit board and functioning properly. Enter Master
Programming mode and verify that the valve type and system type are set
correctly with regard to the unit itself.
Step the unit through a manual regeneration and verify that it functions
correctly. If the error re-occurs unplug the unit and contact technical support.
Perform a Manual Regeneration to reset the error code.
meter is functioning properly.
system capacity has been selected, that the day override is set properly,
Week system, verify that at least one day is set ON. Correct the settings as
necessary.
regeneration. If the error reoccurs, unplug the unit and contact technical
support.