Site Hardware
Connection to an Alarm Panel
Fault Relay Hardware
Alarm When Disabling Video Recording
62
Connect a combination of Fault Relay circuitry and outputs to an alarm panel, preset to
warn your organization if a failure occurs. An output can be configured to respond to a
Response Schedule.
Figure 5-5
Connecting the DVR FAULT RELAY to an External Alarm Panel
INPUT to external
alarm panel
SPOT
MONITOR
1
2
3
4
VIDEO
INPUTS
SERIAL PORT 2
SERIAL PORT 1
VGA
Eleven-Minute Delay
If the DVR fails to function, report alarms or record video due to hardware failure, for more
than 11 minutes, the FAULT RELAY is triggered.
Immediate Trigger
A power outage triggers the relay immediately.
A Rapid Eye LT DVR can be monitored for operator tampering with recording. Refer to the
Rapid Eye™ Hybrid HD and Hybrid LT Digital Video Recorders System Administrator
in the tracing section.
Not
COMMON
SYS FAIL
used
SYS GOOD
FAULT
RELAY
28V, 3A
MAX
COM MON
SYS FA IL
SYS GOOD
FAULT
RELAY
28V, 3A
5
6
7
8
MAX
1 G
2
G
3
ALARM
TELCO
LAN
IN
OUT
115-230V~
50/60 Hz
NOT
5-3A
USED
USB
USB
CONTROL
OUTPUTS
SERIAL
1 G
2
G
3
G
4
G
PORT 3
SERIAL
PORT 4
G
4
G
5 G
6
G
7
G
8
G
INPUTS
ON/OFF
POWER
Guide,