Installation
Leave at least 1 inch
of clearance between
the unit and the
inside walls of the
enclosure.
The temperature at
the unit intake vent
must never exceed
104°F (40°C).

Setting Up LocalView

34
Figure 2-4
Rapid Eye Hybrid LT Unit Air Circulation
Cable space required at the back of the unit.
There are exhaust vents
on both sides of your
Rapid Eye Hybrid LT unit.
Caution
Units that are operating in an environment where the ambient temperature
measured at the intake vent is greater than 104°F (40°C) are not covered
by Honeywell warranty.
Caution
Moisture condensation could damage the DVR. Be aware of possible
moisture condensation when using the unit in a humid area, or in areas
where the temperature fluctuates. Also be aware of possible condensation
when moving units between rooms with extreme temperature changes.
A PC mouse (included) and PC monitor (not included) are needed when using LocalView
to operate a Rapid Eye Hybrid LT DVR. LocalView is available while the DVR is running.
Exhaust and intake
vents on the unit and
enclosure should line
up for proper air
circulation.
1 inch