No.
n014
Mid. Output Frequency
n015
Mid. Output Frequency Voltage
n016
Min. Output Frequency
n017
Min. Output Frequency Voltage
n104
Torque Compensation Time Constant
n111
Slip Compensation Gain
n112
Slip Compensation Gain Time Constant
* 1. Values are doubled for 400 V Class.
* 2. 10.0 V for 5.5 kW and 7.5 kW Inverters of 200-V Class and 20.0 V of
400-V Class.
Factory Settings That Change with the Inverter Capacity
• 200 V Class 3-phase
No.
Name
-
Inverter Capacity
n036 Motor Rated Current
n105 Torque Compensation
Iron Loss
n106 Motor Rated Slip
n107 Motor Line-to-neutral
Resistance*
n108 Motor Leakage
Inductance
n110 Motor No-load
Current
* Sets the value of the motor resistance for one phase.
Name
Unit
kW
0.1
0.2
kW
kW
A
0.6
1.1
W
1.7
3.4
Hz
2.5
2.6
17.99 10.28 4.573 2.575 1.233
mH 110.4 56.08 42.21 19.07 13.4 9.81 6.34 4.22 2.65
%
72
73
9. Specifications
V/f Control
Mode
(n002 = 0)
1.5 Hz
*1 *2
12.0 V
1.5 Hz
12.0 V
*1 *2
0.3 s
0.0
2.0 s
Factory Setting
0.4
0.75
1.5
2.2
kW
kW
kW
kW
1.9
3.3
6.2
8.5
4.2
6.5
11.1
11.8
2.9
2.5
2.6
2.9
0.8
62
55
45
35
Vector Con-
trol Mode
(n002 = 1)
3.0 Hz
*1
11.0 V
1.0 Hz
4.3 V
*1
0.2 s
1.0
0.2 s
3.7
5.5
7.5
kW
kW
kW
14.1 19.6 26.6
19
28.8 43.9
3.3
1.5
1.3
0.385 0.199 0.111
32
26
30
211