Voltage Class
Model
3-phase
CIMR-
V7∗T
Single-phase
Ambient Temperature
Humidity
Storage Temperature
Location
Elevation
Vibration
* 1. Based on a standard 4-pole motor for max. applicable motor output.
* 2. Shows deceleration torque for uncoupled motor decelerating from 60 Hz
with the shortest possible deceleration time.
* 3. The operation level becomes approx. 50% of Inverter rated output current
in case of Inverters of 5.5 kW or 7.5 kW.
* 4. The ground fault here is one which occurs in the motor wiring while the
motor is running. A ground fault may not be detected in the following
cases.
• A ground fault with low resistance which occurs in motor cables or ter-
minals.
• A ground fault occurs when the power is turned ON.
* 5. Minimum permissible load: 5 VDC, 10 mA (as reference value)
* 6. 0P1 to 3P7 are of IP20. Be sure to remove the top and bottom covers
when Inverter 5P5 or 7P5 of open chassis mounting type is used.
* 7. NEMA 1 of 0P1 to 3P7 is optional, while NEMA 1 of 5P5 and 7P5 is pro-
vided as standard.
* 8. Temperature during shipping (for short period).
20P1
20P2
20P4
B0P1
B0P2
B0P4
Open chassis (IP20, IP00): −10 to 50°C
Enclosed wall-mounted NEMA 1 (TYPE 1): −10 to 40°C (not frozen)
95% or less (non-condensing)
−20 to 60°C
*8
Indoor (free from corrosive gases or dust)
1,000 m or less
2
Up to 9.8 m/s
(1G) at 10 to less than 20 Hz,
2
up to 2 m/s
(0.2G) at 20 to 50 Hz
9. Specifications
200 V single-/3-phase
20P7
21P5
22P2
B0P7
B1P5
B2P2
23P7
25P5
27P5
B3P7
-
-