Acceleration/Deceleration Time Selection during Stall Pre-
vention (n116)
With this function, Acceleration Time 2 (n021) and Deceleration Time 2
(n022) can be fixed as the acceleration/deceleration time when moving
to prevent stalling during operation.
Constant
No.
n116
Acceleration/Deceleration
Time Selection during
Stall Prevention
n116 Settings
Setting
0
Acceleration/deceleration time is set to Acceleration/
Deceleration Time 1 or 2.
1
Acceleration/deceleration time is fixed at Acceleration/
Deceleration Time 2 (n021, n022)
• Stall Prevention during Deceleration (n092)
To prevent overvoltage during deceleration, the Inverter automati-
cally extends the deceleration time according to the value of main
circuit DC voltage. When using an optional braking resistor, set
n092 to 1.
Stall Prevention during
Setting
Deceleration
0
Provided
1
Not provided (with braking
resistor mounted)
Name
Function
6. Programming Features
Unit
Setting
Range
-
0=Disabled
1=Enabled
Controls the deceleration
time to prevent overvoltage.
Set
Decel
Time
Factory
Setting
0
Time