Setup; Ac Power; Fuse Replacement - Chauvet Scorpion Storm FX RGB User Manual

Table of Contents

Advertisement

Available languages

Available languages

3. S
ETUP

AC Power

Fuse
Replacement
Page 12 of 64
The Scorpion™ Storm FX RGB has an external auto-ranging power supply and it can
work with an input voltage range of 100 to 240 VAC, 50/60 Hz.
To determine the product's power requirements (circuit breaker, power outlet, and
wiring), use the current value listed on the label affixed to the product's back panel, or
refer to the
Technical
Specifications. The listed current rating indicates the product's
average current draw under normal conditions.
Always connect the product to a protected circuit (circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Disconnect the product from power before replacing the fuse.
1.
Disconnect the product from power.
2.
Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3.
Pry the fuse holder out of the housing.
4.
Remove the blown fuse from the holder.
5.
Replace with a fuse of the exact same type and rating.
6.
Insert the fuse holder back in place and reconnect power.
Spare fuse holder
(inside safety cap)
A spare fuse is not included; however, the safety cap has room for a spare.
Always replace a blown fuse with one of the same type and rating.
Installed fuse
(held by plastic clip)
Safety cap