3. Setup

AC Power

AC Plug

Battery Charge
Notes
Replacing the
Fuse

DMX Linking

WELL Fit User Manual Rev. 1
Each WELL Fit has an auto-ranging battery charger inside the flight case that works with an
input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the power requirements for the
WELL Fit, refer to the label affixed to the product. You can also refer to the
Specifications
chart in this manual.
The listed current rating indicates the maximum current draw during normal operation. For more
information, you may download Sizing Circuit Breakers from the Chauvet website:
www.chauvetprofessional.com.
·
Always connect this product to a protected circuit with an appropriate electrical
ground to avoid the risk of electrocution or fire.
·
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
The WELL Fit charging case comes with a power input cord terminated with a Neutrik
powerCON A connector on one end and an Edison plug on the other end (U.S. market). If the
power input cord that came with your product has no plug, or if you need to change the Edison
plug, use the table below to wire the new plug.
Connection
AC Live
AC Neutral
AC Ground
·
Recharge the battery within three days from last use.
·
Recharge the battery to full capacity before storing this product.
·
For best results, charge the battery in a temperature between 32 ºF (0 ºC) and
95 ºF (35 ºC).
·
When charging the battery, keep the product at no less than 1 m from any open flame or
hot plate.
·
When charging the battery inside the road case charger, keep the road case's cover open.
·
Always charge the battery with the product in an upright position.
·
Do not charge the battery for more than 24 hours.
·
Perform a full discharge/recharge cycle every three months.
The WELL Fit has no external fuse. However, the charging case comes with a replaceable fuse.
1. Disconnect this product from power.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power.
The WELL Fit will work with a DMX controller using a wireless DMX connection. If using other
DMX-compatible products with the WELL Fit, you can control each individually with a single
DMX controller.
Wire (U.S.)
Wire (Europe)
Black
White
Green/Yellow
Brown
Yellow or Brass
Blue
Green/Yellow
Setup
Technical
Screw Color
Silver
Green