Summary of Contents for Chauvet Scorpion Storm FXGB

  • Page 1 LASER LIGHT AVOID DIRECT EYE EXPOSURE CLASS 3R LASER PRODUCT CLASSIFIED PER EN/IEC 60825-1:2007 Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007.
  • Page 2: Table Of Contents

    Table of Contents 1. B EFORE EGIN ..............................3 ..............................3 NCLUDED ............................. 3 NPACKING NSTRUCTIONS ................................3 LAIMS ............................3 ANUAL ONVENTIONS .................................. 3 CONS ..............................4 AFETY OTES ........................5 NTERLOCKED OUSING ARNING ............................5 ASER AFETY OTES ........................
  • Page 3: Before You Begin

    CHAUVET®, upon receipt of the damaged merchandise. Failure to do so in a timely manner may invalidate your claim with the carrier. In addition, retain the container and all the packing material for inspection.
  • Page 4: Safety Notes

    Safety Notes Please read the following notes carefully because they include important safety information about the installation, usage, and maintenance of this product. • Keep this User Manual for future consultation. If you sell this product to another user, be sure that they also receive this document. •...
  • Page 5: Non Interlocked Housing Warning

    Non Interlocked Housing Warning • This unit contains high power laser devices internally. • Do not open the laser housing, due to potential exposure to unsafe levels of laser radiation. • The laser power levels, accessible if the unit is opened, can cause instant blindness, skin burns, and fires.
  • Page 6: Laser Safety Label Reproduction

    Laser Safety Label Reproduction EXPLANATORY, MANUFACTURER’S ID & CERTIFICATION LABEL LASER HAZARD WARNING LABEL LASER APERTURE LABEL NON INTERLOCKED HOUSING LABEL Scorpion™ Storm FXGB User Manual Rev. 4...
  • Page 7: Laser Emission Data

    LASER EXPOSURE Laser light - Avoid direct eye contact! Further guidelines and safety programs for safe use of lasers can be found in the ANSI Z136.1 Standard “For Safe Use of Lasers”, available from the Laser Institute of America: www.laserinstitute.org. Many local governments, corporations, agencies, military and others, require all lasers to be used under the guidelines of ANSI Z136.1.
  • Page 8: Introduction

    2. I NTRODUCTION Product Overview Hanging bracket Bracket Power LED adjustment knob (1 of 2) Audio LED Laser Aperture Scorpion™ Storm FXGB User Manual Rev. 4...
  • Page 9: Product Dimensions

    Product Dimensions Scorpion™ Storm FXGB User Manual Rev. 4...
  • Page 10: Setup

    Proper Usage This product is for overhead mounting only. For safety purposes, CHAUVET® recommends mounting your lighting effect products on steady elevated platforms or sturdy overhead supports using suitable hanging clamps. In all cases, you must use safety cables.
  • Page 11: Data Linking

    CAUTION - USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE Data Linking You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode.
  • Page 12: Perating Nstructions

    4. O PERATING NSTRUCTIONS Navigating the Control Panel Access control panel functions using the four panel buttons located directly underneath the LED Display. Button Function Used to access the menu or to return to a <MODE> previous menu option Scrolls through menu options in ascending <UP>...
  • Page 13: Dmx Channel Values

    DMX Channel Values HANNEL ALUE UNCTION Control Mode 000  019 DMX Mode 020  039 Automatic fast (blue) 040  059 Automatic slow (blue) 060  079 Automatic fast (green) 080  099 Automatic slow (green) 100  119 Automatic fast (blue &...
  • Page 14: Troubleshooting

     power the fixture and it will automatically enter into this mode If you still have a problem after trying the above solutions, contact CHAUVET Technical Support. Scorpion™ Storm FXGB User Manual Rev. 4...
  • Page 15: Returns

    Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #). Products returned without an RMA # will be refused. Call CHAUVET and request RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.
  • Page 16: Technical Specifications

    Technical Specifications WEIGHT & DIMENSIONS Length ................................10.8 in (276 mm) Width................................... 9 in (229 mm) Height ................................9.2 in (234 mm) Weight ................................5.9 lbs (2.7 kg) POWER Autoswitching ............................ 100~240 VAC, 50/60 Hz Fuse ..................................T 1 A, 250 V Power Consumption @ 120 V ..........................

Table of Contents