Fuel Consumption - Lincoln Electric RANGER 9 IM753-A Operator's Manual

Multi-process gasoline engine driven welder and power generator
Table of Contents

Advertisement

B-3
Low Idle - No Load
2200 RPM
High Idle - No Load
3700 RPM
AC CC Weld Output
250 Amps @ 25 Volts
DC CC Weld Output
250 Amps @ 25 Volts
DC CV Weld Output
250 Amps @ 25 Volts
Auxiliary Power
9,000 KVA
WELDER CONTROLS-
Explanation of Symbols that Appear on this Equipment
ON
OFF
ENGINE "ON-OFF" SWITCH
When placed in the "ON" position, this switch
energizes the engine ignition circuit. When placed in
the "OFF" position, the ignition circuit is de-energized
to shut down the engine.
ENGINE "START" PUSH BUTTON SWITCH
Energizes engine starter motor.
"POLARITY" SWITCH
Three STICK/TIG (constant current) polarity settings:
DC+,DC- and AC
Two wire feed (constant voltage) settings:
DC+ and DC-
NOTE: The setting of this switch must match the color
band setting of the Range Switch (both switches must
be set for the same welding process).
CAUTION
Never change the "POLARITY" switch setting
while welding. This will damage the switch.
"RANGE
SWITCH
"
Process
STICK/TIG - (C0instant Current)
Range Settings
WIRE FEED - (Constant Voltage)
Range Setting
OPERATION
Ranger 9 Approximate Fuel Consumption
ONAN P220
.5Gallons/Hour
(1.9 Liters/Hour)
.9 Gallons/Hour
(3.4 Liters/Hour)
1.6 Gallons/Hour
(6.1 Liters/Hour)
1.9 Gallons/Hour
(7.2 Liters/Hour)
1.5 Gallons/Hour
(5.7 Liters/Hour)
1.7 Gallons/Hour
(6.4 Liters/Hour)
Function and Operation
Low Idle
High Idle
Maximum Current
on Each Setting
45,90,120,
6
160, 200, 250
3
LOW,MED,HIGH
RANGER 9
CAUTION
Never change the "RANGE" Switch setting while
welding. This will damage the switch.
------------------------------------------------------------------------
CONTROL
"
"
Provides a fine welding current adjustment within the
Range Switch settings in the STICK/TIG mode and
welding voltage control with the Range switch set in
the wire feed mode.
"CONTROL AT WELDER /
REMOTE CONTROL" SWITCH
The toggle switch on he control panel labeled "CON-
TROL AT WELDER" and "REMOTE CONTROL" gives
the operator the option of controlling the output at the
welder control panel or at a remote station. Remote
connections are made at the 6-pin or 14-pin amphenol
connector.
For remote control, the toggle switch is set in the
"REMOTE CONTROL" position.
For control at the welder control panel, the toggle
switch is set in the "CONTROL AT WELDER" position.
"WELDING TERMINALS" SWITCH
The Toggle switch labeled "WELDING TERMINALS
ALWAYS ON"
and
REMOTELY CONTROLLED" is used to control the
operation of the welder output contactor.
With the switch in the "ALWAYS ON" position, the out-
put contactor is closed at LOW and HIGH idle.
B-3
KOHLER
20 H.P. CH20S
.4 Gallons/Hour
(1.5 Liters/Hour)
1.0 Gallons/Hour
(3.8 Liters/Hour)
1.5 Gallons/Hour
(5.7 Liters/Hour)
1.7 Gallons/Hour
(6.4 Liters/Hour)
1.6 Gallons/Hour
(6.1Liters/Hour)
1.7 Gallons/Hour
(6.4 Liters/Hour)
SWITCH
"WELDING TERMINALS