F-3
TO WORK
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
THE ENGINE WELDER OPERATING MANUAL.
N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELCTRODE POLARITY, POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.
PLACE WELDING TERMINAL SWITCH TO "REMOTELY CONTROLLED" POSITION.
N.B. WELDING CABLE MUST BE OF PROPER CAPCITY FOR THE CURREENT AND DUTY CYCLE OF IMMEDIATE AND FUTRE
APPLICATIONS. SEE OPERATING NMANUAL.
N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION.
RANGER 9 TO K867 ADAPTER CONNECTION DIAGRAM
14 PIN
AMPHENOL
ELECTRODE
TO WORK
TO WORK
CAUTION :
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
THE ENGINE WELDER OPERATING MANUAL.
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. USE POLARITY SWITCH TO SET DESIRED POLARITY, POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION
RELAY TO CLOSE LEADS 2 & 4.
N.E. REFER TO POWER SOURCE INSTRUCTION MANUAL FOR MAXIMUM AUXILIARY CURRENT DRAW.
DIAGRAMS
RANGER 9
ELCTRODE
-XX INPUT
IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
IDLE
WARNING
Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.
Do not touch electrically live parts.
SPARE
K867 UNIVERSAL
ADAPTER PLUG
GND
ELECTRODE CABLE
TO WIRE FEED UNIT
RANGER 9
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.
81
82
NOT USED ON RANGER POWER SOURCES
2
CONNECT TOGETHER FOR
4
WELDING OUTPUT
41
42 VAC
42
N.E.
31
115 VAC
32
POWER SOURCE FRAME CONNECTION
21
WIRE FEEDER VOLTMETER CONNECTION
CONNECTS TO (WORK TERMINAL) OF POWER SOURCE
77
10K
76
REMOTE OUTPUT CONTROL
MIN.
75
TO
K867
12-16-93
M17092
N.C.
N.D.
2
TO
WIRE
FEEDER
4
12-16-93
M17093
F-3