E-2
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
No welder or output power.
Engine will not idle down to low
speed.
Engine will not go to high idle when
attempting to weld.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
POSSIBLE AREAS OF
MISADJUSTMENTS
1.
Open in miscellaneous leads.
2.
Open lead in flashing or field
circuit.
3.
Faulty rotor.
4.
Faulty Potentiometer (R1).
5.
Faulty stator Field winding.
6.
Faulty Field rectifier (D2).
7.
Faulty P.C. Board.
1.
Idler switch on High Idle.
2.
Insufficient voltage present
between terminals #213 and
#5E. (Voltage should be 12V
DC).
3.
External load on welder or
auxiliary power.
4.
Faulty wiring in solenoid circuit.
5.
Faulty idler solenoid.
6.
Faulty P.C. Board.
1.
Poor work lead connection to
work.
2.
No voltage signal from the
current sensor.
3.
No open circuit voltage on
output studs.
4.
Faulty P.C. Board.
CAUTION
RANGER 9
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
E-2