Analog E-E Y Signal Output Level Check (Va-102 Board); Analog E-E Chroma Signal Output Level Check (Va-102 Board) - Sony DSR-20MD Service Manual

Digital video cassette recorder
Table of Contents

Advertisement

3. Analog E-E Y Signal Output Level Check
(VA-102 Board)
Mode
E-E
Signal
Color bar (S VIDEO input) (Note 1)
Measurement Point
Pin qd of CN401 (CL436)
Measuring Instrument
Oscilloscope
A = 0.714 ± 0.02 V (NTSC)
Specified Value
A = 0.700 ± 0.02 V (PAL)
Note 1: Set "S VIDEO" mode with the INPUT SELECT button
on the front panel.
Note 2: Terminate the Y signal terminal of the S video output
terminal using a 75 Ω resistor.
75 Ω resistor (Parts code: 1-247-804-11)
Checking method:
1) Check that the Y signal level (A) is the specified value.
For NTSC model
H
For PAL model
White (100%)
H
Fig. 5-3-15.
White (100%)
A
A
4. Analog E-E Chroma Signal Output Level Check
(VA-102 Board)
Mode
Signal
Measurement Point
Measuring Instrument
Specified Value
Note 1: Set "S VIDEO" mode with the INPUT SELECT button
on the front panel.
Note 2: Terminate the Chroma signal terminal of the S video out-
put terminal using a 75 Ω resistor.
75 Ω resistor (Parts code: 1-247-804-11)
Checking method:
1) Check that the burst signal level (A) is the specified value.
For NTSC model
For PAL model
5-76
E-E
Color bar (S VIDEO input) (Note 1)
Pin qa of IC401 (CL435)
Oscilloscope
A = 286 ± 20 mV (NTSC)
A = 300 ± 20 mV (PAL)
A
H
A
H
Fig. 5-3-16.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsr-20mdp

Table of Contents