6-3-11. TAPE PATH CHECK
2 It will be okayed, if there is no curls at the guides, capstan, etc. (a part) in the M and m mode.
3 After adjustment and check, return the data set by the adjusting remote commander to the original value.
The following is ideal, but, it is satisfactory if the RF waveform is normal.
Should be along the upper flange.
Leaving space is available.
TG1
TG2
TG3
Leaving space is available.
Note: Do not rotate the adjustment screw.
TG3
TG2
TG1
Tracking tape (XH2-1)
POWER
Leaving space is available.
Capstan
Drum
Tape
TG6
TG7
Leaving space is available.
Capstan
Drum
TG6
TG7
TG8
1 Playback.
Tracking tape
(XH2-1 AST)
Note: Tape Path (Refer
to page 5-4) (J-5)
DECK
XH2-1
5-54
CUE
REV
TG8
Pinch roller