Tamper Alert

If the system was triggered while away, the LED will flash to indicate which zone triggered the system after
disarming and turning the ignition ON. The LED indication will repeat 8 times.
LED Flashes (60 seconds):
1 flash
2 flashes
3 flashes
4 flashes
6 flashes
example: flash-flash-pause-flash-flash-pause = shock sensor
Silent Arming/Disarming
The G5/G2 Series system can be programmed to operate the system without Arm/Lock and Disarm/Unlock
chirp/honk confirmations. When programmed for full-time silent operation, the siren will sound only when
the system is triggered.
The system is also capable of temporary silent operation if desired. Pressing the Shift button before
Arming/Locking or Disarming/Unlocking, the system will bypass the chirp/honk confirmations and allow
one-time silent operation.
Note: The open zone warning chirps will not be bypassed when the system is Armed or Disarmed silently.*

Passive Arming

When programmed for the optional Passive Arming feature, the system arms itself automatically, each time
the ignition is turned off and all of the doors, hood, and trunk are closed.
To start the Passive Arming Process:
1. Turn off the ignition.
2. Open the door and exit the vehicle.
· Once all doors are closed and the dome light is off, the LED will begin flashing rapidly.
· The parking lights will flash twice indicating the Passive Arming sequence has begun.
3. After 30 seconds,
· The siren will chirp.
· The parking lights will flash.
· The doors will lock.***
· The status LED will begin flashing slowly.
4. The system is now armed.
** * If the Passive Locking feature is selected.
=
optional sensor
=
shock sensor
=
network based sensor
=
door
=
hood/trunk
G5.2W, G2.2W, A4.2W, A1.2W - Page 11