7 Periodicity Abnormal (Refer to Figure 7-2 E )
Periodicity
94 mm
Image Drum
49.6 mm
Development Roller
54.8 mm
Sponge Roller
37.7 mm
Charge Roller
89 mm
Upper Roller
125 mm
Lower Rolle
After replacing the Image Drum Cartridge, Fuser Unit or Belt Unit, reset the counter from
Note
the User Maintenance Mode.
42930511TH Rev. 2
Malfunction Details
Replace the image drum cartridge.
Replace the image drum cartridge.
Replace the image drum cartridge.
Replace the image drum cartridge.
Replace the fuser unit.
Replace the fuser unit.
Oki Data CONFIDENTIAL
Restoration Method