Step
29.
Navigate to ini Parameters in the left pane. In the Parameter Name field, select
ModemBypassPayloadType from the pull-down menu. Enter 0 in the Enter Value
field. Click on Apply New Value.
A value of 0 in the payload type indicates a G.711mu call. By default, the MP-118
uses a proprietary value for the payload type of modem calls so they can be
distinguished from other G.711mu calls.
30.
To save the configuration, return to the administrative web page and select
Maintenance in the left pane. Click the BURN button.
CTM; Reviewed: