Checking The Condensate Trap - Baxi MainEco Combi 24 Installation And Service Manual

Wall mounted gas condensing boiler
Hide thumbs Also See for MainEco Combi 24:
Table of Contents

Advertisement

8. Checking and maintenance
2
3
4
56
1
5
6
R000431-B
Baxi MainEco Combi and System 24 - 28 - 35 / 18 - 24
8.2.9.

Checking the condensate trap

CAUTION
First remove the front housing of the boiler so that you can
disconnect the condensate trap.
1. Move the lever underneath the hydroblock to the right to
disconnect the condensate trap.
2. Remove the condensate trap and clean it.
3. Replace the seal ring for the condensate trap.
4. Fill the condensate trap with water up to the mark.
5. Press the condensate trap firmly into the j opening provided for
it underneath the boiler. The condensate trap must click into place.
6. Check whether the condensate trap is solidly fitted in the boiler.
02092014 - 7619497-02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maineco combi 35Maineco system 18Maineco combi 28

Table of Contents