Outlets - Baxi MainEco Combi 24 Installation And Service Manual

Wall mounted gas condensing boiler
Hide thumbs Also See for MainEco Combi 24:
Table of Contents

Advertisement

5. Installation
R
I
F
Terminal position with minimum distance
(1)
Directly below an opening, air brick, opening windows, etc.
A
Above an opening, air brick, opening window etc.
(1)
B
(1)
Horizontally to an opening, air brick, opening window etc.
C
Below gutters, soil pipes or drain pipes.
(2)
D
(2)
Below eaves.
E
Below balconies or car port roof.
(2)
F
From a vertical drain pipe or soil pipe.
(2)
G
(2)
From an internal or external corner.
H
Above ground, roof or balcony level.
I
From a surface or boundary line facing a terminal.
J
From a terminal facing a terminal (Horizontal flue).
K
From a terminal facing a terminal (Vertical flue).
From an opening in carport (e.g. door, window) into the dwelling.
L
Vertically from a terminal on the same wall.
M
Horizontally from a terminal on the same wall.
N
From adjacent wall to flue (vertical only).
R
From an adjacent opening window (vertical only).
S
Adjacent to windows or openings on pitched and flat roofs.
T
Below windows or openings on pitched roofs.
U
(1) In addition, the terminal should be no nearer than 150 mm to an opening in the building fabric formed for the purpose of accommodating a
built-in element such as a window frame.
(2) Only one 25 mm clearance is allowed per installation. If one of the dimensions D, E, F, G or H is 25 mm then the remainder MUST be as
shown in brackets, in accordance with BS 5440-1
30
T
J,K
N
M
I
L
Likely flue positions requiring a flue terminal guard
Baxi MainEco Combi and System 24 - 28 - 35 / 18 - 24
5.7.2.

Outlets

When codes of practice dictate the use of a terminal guard
use a suitable guard of stainless steel construction. There
must be a clearance of at least 50 mm between any part of
the terminal and the guard.
U
D
A
C
E
I
S
B
F
A
A
G
H
H
I
I
J,K
02092014 - 7619497-02
R000707-A
300 mm
300 mm
300 mm
25 (75) mm
25 (200) mm
25 (200) mm
25 (150) mm
25 (300) mm
300 mm
600 mm
1200 mm
600 mm
1200 mm
1500 mm
300 mm
300 mm
1000 mm
600 mm
2000 mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maineco combi 35Maineco system 18Maineco combi 28