Testing The System - Bosch Solution 144 Quick Start Manual

Hide thumbs Also See for Solution 144:
Table of Contents

Advertisement

Solution 144
Quick Start Guide
System > System Options >
Installer Options
1 Report Installer
2 Report Prog Change
3 Restrict Installer PIN
4 Reserved
5 Auto Exit Install 2hr
6 Auto Exit Service 2hr
7 Multi Tenant Mode
8 Allow Defaulting
(*** System Wide Parameter ***)
Use the [] and [] keys to scroll the list of options. Select
the option required, then press [ON] or [OFF] to enable or
disable. A [] will display to indicate option set. Press [OK]
to save when finished.
System > System Options >
Language
0 - English
1 - Alternate Language
Enter digits 0 – 1 to program the language required, then
press [OK] to save.
System > System Options >
Site Name
1
M y A
l
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
System > System Testing >
Walk Test All Zones
Battery Test
52
MENU 7-7-4
MENU 7-7-5
MENU 7-7-7
Characters
a
r m
MENU 7-9-0
MENU 7-9-1
Te st ing The Syste m
You will need to be in programming mode before accessing
the test functions listed below.
N
Walk Test
Y
Use the walk test command MENU 3-9-0 to test and verify
N
that all zones work correctly.
N
Y
External Audible Test
Y
Use MENU 4-9-0 to test and verify that all horn speakers
operate. This test will sound the horn speaker for two
N
seconds.
Y
Internal Audible Test
Use MENU 4-9-1 to test and verify that all 12 VDC sirens
operate. This test will sound the siren for two seconds.
Strobe Test
Use MENU 4-9-2 To test and verify that the strobe operates.
This test will turn on the strobe until you manually stop the
test.
Fire Audible Test
Use MENU 4-9-3 to test and verify that all 12 VDC sirens
0
operate. This test will sound the siren for two seconds.
Battery Test
Use MENU 7-9-1 to test the back-up battery that is
connected to the control panel.
Communication Test
Use MENU 5-9-0 to test the telephone reporting capability
of the control panel. You can also activate a communication
test by holding down the Test / Mail key on the keypad.
32
Bosch Security Systems 10/12 BLCC600R

Advertisement

Table of Contents
loading

Table of Contents