Inputs > Global Input Options >
EOL Value
(*** System Wide Parameter ***)
00 - No EOL
01 - 1k0 Ohm
02 - 1k5 Ohm
03 - 2k2 Ohm
04 - 2k7 Ohm
05 - 3k3 Ohm
06 - 4k7 Ohm
07 - 5k6 Ohm
Use [] and [] keys or enter 0 - 15, then press [OK] to
program globally the EOL resistor for all zones.
Inputs > Global Input Options >
Keyswitch Options
(*** System Wide Parameter ***)
00 - Latching All On/Off
01 - Latching All On
02 - Latch Part On/Off
03 - Latching Part On
04 - Latching Off
Use [] and [] keys or enter 0 - 9, then press [OK] to
program how the keyswitch will operate.
Inputs > Global Input Options >

Input Options

1 Tamper On Short
2 Reserved
3 Response Time 500msec
4 Reserved
5 Keyswitch Open Close
6 Alarm On Tamper
7 Reserved
8 Reserved
(*** System Wide Parameter ***)
Use the [] and [] keys to scroll the list of options. Select
the option required, then press [ON] or [OFF] to enable or
disable. A [] will display to indicate option set. Press [OK]
to save when finished.
Bosch Security Systems 10/12 BLCC600R
MENU 3-4-0
0 5
08 - 6k8 Ohm
09 - 8k1 Ohm
10 - 10k Ohm
11 - 6K8 Alarm + 2k2 Tamp
12 - 10k Alarm + 10k Tamp
13 - 22k Ohm
14 - 3k3 Alarm + 6k8 Tamp
15 - Split EOL 3k3 //6k8
MENU 3-4-1
0 0
05 - Pulse All On/Off
06 - Pulse All On
07 - Pulse Part On/Off
08 - Pulse Part On
09 - Pulse Part Off
MENU 3-4-2
Inputs > PGM Input >
Keyswitch Options
00 - Disabled
01 - Latching On/Off
02 - Pulse On/Off
Enter 0 - 8 + [OK] to select the interface method used for
the given RF receiver.
Inputs > Tamper Inputs >
Tamper Options
1 Display Panel Tpr
2 Report Panel Tpr
3 Audible Panel Tpr
4 Display Expander Tpr
5 Report Expander Tpr
6 Audible Expander Tpr
7 Reserved
8 Reserved
Use the [] and [] keys to scroll the list of options. Select
the option required, then press [ON] or [OFF] to enable or
disable. A [] will display to indicate option set. Press [OK]
to save when finished.
Inputs > Input Testing >
Walk Test All Zones
Inputs > Input Testing >
N
Walk Test A Zones
N
N
Inputs > Input Testing >
N
Sensor Watch Time
Y
(*** System Wide Parameter ***)
N
N
Enter 0 – 255 + [OK] to program the sensor watch time in
N
days (0 = Disabled).
Solution 144 Quick Start Guide
MENU 3-5-0
0 0
03 - Simple RF On/Off
04 - Bosch Serial Rcvr
05 - Crow Serial Rcvr (TBA)
MENU 3-6-0
MENU 3-9-0
MENU 3-9-1
MENU 3-9-2
0 3 0
Days
Y
Y
Y
Y
Y
Y
N
N