Zone Default Table; Table 20: Zone Defaults - Bosch Solution 144 Quick Start Manual

Hide thumbs Also See for Solution 144:
Table of Contents

Advertisement

Solution 144
Quick Start Guide
Zo n e D efa ul t Ta bl e
The table below list the default values for all zone parameters in the Solution 144. By default, zones 5 to 16 are set as
Instant zones and zones 17 to 144 are set as Not Used. Zones marked as Not Used do not require EOL resistors to be fitted.
Programming
Zone Name
Zone Type
Area Assignment
Pulse Count
Pulse Count Time
Door Assignment
Report Route
Reporting Options
Lockout Dialler
Report Alarm
Report Troubles
Report Bypass
Report Restores
Delay Reporting
Zone Options
Lockout Siren
Silent Alarm
Inverted Seal
Bypass Allowed
Sensor Watch
Armed In Part On
No EOL Required
Test On Exit
Inputs > Zone Properties >
Report Options
1 Lockout Dialler
2 Report Alarm
3 Report Troubles
4 Report Bypass
5 Reserved
6 Reserved
7 Report Restores
8 Delay Reporting
Use the [] and [] keys to scroll the list of options. Select
the option required, then press [ON] or [OFF] to enable or
disable. A [] will display to indicate option set. Press [OK]
to save when finished.
32
Zone 1
Zone 2
Zone 1
Zone 2
1 = Delay 1
5 = Handover
1
1
0
0
120
120
0
0
2
2
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
Y
Y
N
N
N
N
Y
Y
N
N
Y
Y
N
N
N
Y
MENU 3-1-7
Zone 3
Zone 3
5 = Handover
5 = Handover
1
0
120
0
2
Y
Y
Y
Y
Y
N
Y
N
N
Y
N
Y
N
Y

Table 20: Zone Defaults

Inputs > Zone Properties >
Zone Options
Y
1 Lockout Siren
Y
2 Silent Alarm
Y
3 Inverted Seal
Y
4 Bypass Allowed
N
5 Sensor Watch
N
6 Armed In Part On
Y
7 No EOL Required
N
8 Test On Exit
Use the [] and [] keys to scroll the list of options. Select
the option required, then press [ON] or [OFF] to enable or
disable. A [] will display to indicate option set. Press [OK]
to save when finished.
Inputs > RF Zone >
Add RF Device
Delete RF Device
Test RF Device
Zone 4
Zones 5 - 16
Zone 4
Zone 5 to 16
3 = Instant
1
1
0
0
120
120
0
0
2
2
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
Y
Y
N
N
N
N
Y
Y
N
N
Y
Y
N
N
Y
Y
Bosch Security Systems 10/12 BLCC600R
Zones 17 - 144
Zone 17 to 144
0 = Not Used
1
0
120
0
2
Y
Y
Y
Y
Y
N
Y
N
N
Y
N
Y
N
Y
MENU 3-1-8
Y
N
N
Y
N
Y
N
Y
MENU 3-3-0
MENU 3-3-1
MENU 3-3-2

Advertisement