3.0 Codepad Indicators

Figure 1: CP5 Eight Zone LED Codepad
Figure 2: CP5 Eight Zone LCD Codepad
The codepad is the communications interface
between you and your alarm system. Use the
codepad to issue commands. The codepad offers
both visual and audible indications that guide you
through general operation.
The codepad incorporates a number of indicators.
Eight zone indicators show the status of each zone
and four other indicators show general status.
3.1

Zone Indicators

The zone indicators (1 to 8) display
1 2 3 ....
the status of the zones. Table 1 lists the
status that the indicators display (such
as, Zone Sealed/Zone Unsealed).
Table 1: Zone Indicators
Status
Definition
On
Zone is unsealed.
Off
Zone is sealed.
Flashing fast
Zone is in alarm.
(0.25 sec on/
0.25 sec off)
Flashing slow
Zone is manually isolated or
(1 sec on/1 sec off)
selected to be isolated.
Bosch Security Systems | 7/05 | F01U009494B
CC404 | Operators Guide | 3.0
3.2

AWAY Indicator

The AWAY indicator shows the system
is armed in AWAY Mode. The AWAY
indicator also flashes in unison with the
STAY indicator when programming
the control panel.
Refer to Section 4.1 Arming in AWAY
Mode on page 7 for information on the
different methods of arming the system
in AWAY Mode.
Table 2: AWAY Indicator
Status
Definition
On
System is armed in AWAY Mode.
Off
System is not armed in AWAY Mode.
3.3

STAY Indicator

The STAY indicator shows the system is
armed in STAY Mode 1 or STAY
Mode 2. The STAY indicator also flashes
in unison with the AWAY indicator when
programming the control panel.
Refer to Section 4.2 Arming in STAY Mode
1 on page 7 and Section 4.3 Arming in
STAY Mode 2 on page 7.
Table 3: STAY Indicator
Status
Definition
On
System is armed in STAY Mode
1 or STAY Mode 2.
Off
System is not armed in STAY
Mode 1 or STAY Mode 2.
Flashing twice a
Zone Isolating Mode or setting
second
STAY Mode 2 zones.
Flashing once every
Day alarm status – day alarm
3 seconds
turned on.
3.4

System Disarmed

This indicator and the
when the system is disarmed.