Product Identification; Local Codes; Optional Remote Control Accessories; Unpacking - Superior VD1824NR Operation Instructions Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

PRODUCT
IDENTIFICATION
Six
Piece
Log Set
Left
Side
Piezo
Ignitor
Front
Flame
Adjustment
Knob
Figure 1 - Product Identification
OPTIONAL REMOTE
CONTROL ACCESSORIES
There are five optional remote controls that can
be purchased separately for:
• wall switch
• wall thermostat
• hand-held ON/OFF remote
• hand-held thermostat remote
• TSRC hand-held touch screen remote
See Accessories, page 34.
The wall thermostat or hand-held thermostat
may not be used where vented decorative
listing is required.

UNPACKING

CAUTION: Do not remove data
plates from grate assembly. Data
plates contain important warranty
and safety information.
1. Remove logs and heater base assembly
from cartons.
Note: Do not pick up heater base assem-
bly by burners. This could damage heater.
Always handle base assembly by grate.
2. Remove all protective packaging applied
to logs and heater for shipment.
3. Check heater for any shipping damage.
If heater is damaged call INNOVATIVE
HEARTH PRODUCTS at 1-800-655-2008
for replacement parts before returning to
dealer.
126839-01A
Right
Side
Base
Assembly
Control
Knob
www.SuperiorFireplaces.US.com

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note: Where listed vented decorative logs
are required, thermostat operation is not
permitted.
State of Massachusetts: The installation
must be made by a licensed plumber
or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters
shall provide to each purchaser a copy of
527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.

PRODUCT FEATURES

OPERATION
This heater is clean burning. It requires no
outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by
both realistic flames and glowing coals. This
heater is designed for vent-free operation
with flue damper closed. It has been tested
and approved to ANSI Z21.11.2 standard for
unvented heaters. State and local codes in
some areas prohibit the use of vent-free heat-
ers. This heater may also be operated as a
vented decorative (ANSI Z21.60) product by
opening the flue damper.
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free
room heaters. The ODS/pilot shuts off the
heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system re-
quires no matches, batteries or other sources
to light heater.
5