VD1824PR
• Rating: 25,000/36,000 Btu/hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 14" w.c., Minimum - 11" w.c.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• for propane/LP units, propane/LP gas sup-
ply may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Contact authorized dealers of this product.
If they can't supply original replacement
part(s), call INNOVATIVE HEARTH PROD-
UCTS at 1-800-655-2008.
126839-01A
SPECIFICATIONS
REPLACEMENT PARTS
WIRING DIAGRAM
www.SuperiorFireplaces.US.com
VD1824NR
• Rating: 25,000/36,000 Btu/hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 10.5" w.c., Minimum - 5" w.c.
TECHNICAL SERVICE
You may have further questions about instal-
lation, operation or troubleshooting. If so, con-
tact INNOVATIVE HEARTH PRODUCTS at
1-800-655-2008. When calling please have
your model and serial numbers of your heater
ready.
You can also visit our web site at
www.IHP.US.com.
When calling, have ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural
gas)
• purchase date
Usually, we will ask you to return the part to
the factory.
Thermopile
33