Minimum Noncombustible Material; If Using Mantel; Mantel Clearances; Determining Minimum Mantel Clearance - Superior VD1824NR Operation Instructions Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

Minimum Noncombustible Material

Clearances
If Not Using Mantel
Note: If using a mantel proceed to If Using
Mantel. If not using a mantel, follow the infor-
mation on this page.
You must have noncombustible material(s)
above the fireplace opening. Noncombustible
materials (such as slate, marble, tile, etc.) must
be at least 1/2 inch thick. With sheet metal, you
must have noncombustible material behind
it. Noncombustible material must extend at
least 8" up (for all models). If noncombustible
material is less than 12", you must install the
fireplace hood accessory (for all models). See
Figure 5 for minimum clearances.
Noncombustible
Material Distance
(A)
12" or more
Between 8" and
12"
Less than 8"
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace
10
INSTALLATION
Requirements for Safe
Installation
Noncombustible material
okay.
Install fireplace hood
accessory (GA6050 or
GA6053 see Accesso-
ries, page 34).
Noncombustible material
must be extended to at
least 8". See Between
8" and 12", above. If you
cannot extend material,
you must operate heater
with flue damper open.
www.SuperiorFireplaces.US.com
Continued

If Using Mantel

You must have noncombustible material(s)
above the fireplace opening. Noncombustible
materials (such as slate, marble, tile, etc.) must
be at least 1/2" thick. With sheet metal, you
must have noncombustible material behind it.
Noncombustible material must extend at least
8 inches up (for all models). If noncombustible
material is less than 12", you must install the
fireplace hood accessory (24" Models Only).
Even if noncombustible material is more than
12", you may need the hood accessory to
deflect heat away from your mantel shelf. See
Figure 5, and Figures 6 and 7 (page 11) for
minimum clearances.
IMPORTANT: If you cannot meet these mini-
mum clearances, you must operate heater
with chimney flue damper open. Go to Install-
ing Damper Clamp Accessory for Vented
Operation, page 11.

MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet the clearances
listed below, you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).
Minimum
Noncombustible
Material
Figure 6 - Minimum Mantel Clearances
Mantel Shelf
10"
8"
6"
2 ½"
(A)
12"
18"
20"
22"
8"
8"
14"
17"
Distances to
Minimum Non-
Underside of
Combustible
Mantel
Material Height
Without Using Hood
Underside of
Mantel Shelf
Log Set
24"
24" Models
20"
18" Model
Top of
Fireplace
Opening
126839-01A