Download Print this page

Specifi Cations - Follett Maestro Chewblet 400 Series Installation & Service Manual

Ice machine and top kit for lancer countertop ice and beverage dispensers
Hide thumbs Also See for Maestro Chewblet 400 Series:

Advertisement

Specifi cations

Electrical
Model number
MC400 series ice machine
Ambient specifi cations
Air temperature
Water temperature
Water pressure
Plumbing
Your new ice machine is equipped with a drain line to simplify draining the evaporator and fl oat reservoir. The
tube labeled "fl oat/evap drain" is for SERVICE USE ONLY and must NOT be connected to the ice machine drain.
Water line sizes
Drain line sizes
Slope to drain
Water shut-off recommended within 10 feet (3m), drain to be hard-piped and insulated
Separate drains for ice machine and condenser. To prevent back fl ow, do NOT connect drains.
Follett recommends installation of a Follett water fi lter system (part# 00130229) in ice machine inlet water line
Field Wiring: countertop and wall mount dispensers with RIDE™ remote
ice delivery model ice machines
Consult enclosed D400A/W, R400A/W, MCD400A/W manual.
115/60/1
100 F/38 C max.
90 F/32 C max.
70 P.S.I. max. (482kPA) 10 P.S.I min. (89kPA)
Make up water (inlet to fl oat)
Condenser (water-cooled only)
Ice machine drain
Condenser (water-cooled only)
1/4" per foot (6mm per 30.4cm run)
4
Full load amps
11.0 amps
50 F/10 C min. (best performance below 80 F/27 C)
40 F/4 C min. (best performance below 70 F/21 C)
1/4" min.
3/8" min.
3/4" min.
1/2" min.
1/2" min.
Max. fuse size
20 amps

Advertisement