Troubleshooting - RIDGID RP 330-B Manual

Pressing tool
Hide thumbs Also See for RP 330-B:
Table of Contents

Advertisement

Troubleshooting

SYMPTOM
Tool will not turn ON
when ON/OFF button on
display panel is pressed.
Tool turns OFF either
when trigger is de-
pressed or in the middle
of a press cycle. Red
LED glows.
Yellow LED blinks
repeatedly as long as
tool is turned ON and
tool functions properly.
Yellow LED glows con-
tinuously and tool will
not begin press cycle
when trigger switch is
depressed.
Red LED blinks repeated-
ly and tool will not begin
press cycle when trigger
switch is depressed.
Yellow LED glows when
tool is turned ON.
Jaws are locked onto
fitting.
The pressed connections
produced are not com-
plete.
POSSIBLE REASONS
Electric cord damaged.
Battery is completely discharged or battery has
failed or power cord not properly inserted into
outlet.
Battery not properly inserted into handle of tool.
Battery is too low.
Tool or battery is too cold or too hot.
Scheduled maintenance/recalibration is required
after 30,000 presses.
Scheduled maintenance/recalibration is manda-
tory after 32,000 presses. Tool is "locked" and
will not function until tool is serviced.
Accessory mounting pin not fully closed.
Tool malfunction detected.
Press was not successfully completed.
Used wrong jaw set for the tube size or material.
The tool was not square to the tube.
Jaw contour was not aligned with the fitting contour.
Tool is in need of repair.
Ridge Tool Company
RP 330 Pressing Tool
SOLUTION
Inspect the cord and replace if necessary.
Insert fully charged battery/recharge dead battery
or unplug and replug power cord.
Check to assure battery is fully inserted.
Insert fully charged battery/recharge dead battery.
Bring tool and battery to correct operating range
between 15°F (-10°C) to 122°F (50°C) by allow-
ing the tool to sit in a conditioned room.
NOTE! Fitting must be repressed if tool stops
in the middle of a press cycle. Failure
to do so may result in a leaking fitting.
Contact Test Equipment Depot
Contact Test Equipment Depot
Insert accessory mounting pin to the fully closed
position.
Unplug and replug power cord or remove and rein-
sert fully charged battery. Be sure to repress fitting.
If
LED's
continue
to
Equipment Depot
Push pressure release valve to remove jaws from fit-
ting. Inspect and repress fitting.
Install the correct jaw set.
Redo the joint with new fitting and new tube.
Make sure that the tool is square to the tube.
Redo the joint with new tube and new fitting.
Make sure the jaw contour is aligned with the
fitting contour.
Contact Test Equipment Depot