RP 330 Diagnostic Codes

LED
Status
Green
Glows
Blinks
Red
Blinks
Glows
Yellow
Blinks
Glows
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
12
Description
Tool ON.
Out of acceptable voltage range
— Cordless Tools: Replace battery with a fully charged battery.
— Corded Tools: Connect tool to a reliable voltage supply. If using extension cord,
use 16 AWG for 50' or less, 14 AWG for 50' to 100'.
Jaws mounting pin not fully engaged. Insert pin.
Out of temperature range -10°C (15°F) to 50°C (122°F).
Service indicator after 30,000 cycles. NOTE: Tool will lock after 32,000 cycles.
Machine is locked – Service after 32,000 cycles or after a malfunction.