2.1.7 Control Box Section
The control box (Figure 2-6) includes the manual
operation switches; circuit breaker (CB-1); compressor,
fan and heater contactors; control power transformer;
fuses; key pad; display module; current sensor module;
controller module and the communications interface
module.
1
2
18
17
1.
Compressor Phase A Contactor
2.
Compressor Phase B Contactor
3.
Heater Contactor
4.
Display Module
5.
Communications Interface Module
6.
Controller/DataCORDER Module (Controller)
7.
Key Pad
8.
Remote Monitoring Receptacle
9.
Controller Battery Pack
T-317
3
16
15
14
13
Figure 2-6 Control Box Section
2.1.8 Communications Interface Module
The communications interface module is a slave
module which allow communication with a master
central monitoring station. The module will respond to
communication and return information over the main
power line. Refer to the master system technical manual
for further information.
4
5
12
11
10.
Interrogator Connector (Box Location)
11.
Fan Mode Switch
12.
Emergency Bypass Switch
13.
Control Transformer
14.
Evaporator Fan Contactor - High
15.
Evaporator Fan Contactor - Low
16.
Condenser Fan Contactor
17.
Circuit Breaker -- 460V
18.
Current Sensor Module
2-6
6
10
9
8
7