Heat Source Lockout; Stages / Latch For Evolution - Bryant Evolution Connex SYSTXBBECW01-A Installation Instructions Manual

Evolution connex control
Hide thumbs Also See for Evolution Connex SYSTXBBECW01-A:
Table of Contents

Advertisement

6.3.5.

Heat Source Lockout

First touch SETUP, then touch HEAT SOURCE LOCKOUTS to set up the
parameters for the AC/Heat Pump unit.
For hydronic heat applications, this option allows the installer to set the lockout
temperatures below the which only the hydronic coil will operate, and the lockout
temperature above which the hydronic coil will not operate. After the selections are
made, touch SAVE.
HP Lockout: Adjustable from - - 20 to 55_F (- - 28 to 13_C) or None
S
Default = None
d
Furnace, Electric Heat or Hydronic Lockout: Adjustable from 15 to 55_F
S
(- - 9 to 13_C) or None
Default = None
d
Defrost with Furnace, Electric Heat or Hydronic: Yes or No
S
Default = Yes
d
6.3.6. Stages / Latch for Evolution V
For Evolution V heat pumps, the cooling and heating stage/latch can be changed.
Select cooling or heating next to stages/latch. The maximum stage and the
minimum stage can be selected. The minimum selected stage can be locked- - in or
set based upon the outside temperature. See screen shots below.
44
A12149

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents