4.3.

Location

ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury
or death.
Disconnect power before routing control wiring.
All wiring must comply with national, local, and state codes.
4.3.1.

Wall Control

The Evolution Connex Control is the command center for the Evolution System. It
should be located where it is easily accessible and visible to the adult homeowner
or end user. For accurate temperature measurement, the following guidelines should
be followed:
The Evolution Connex Control and Remote Room Sensors SHOULD be mounted:
Approximately 5- - ft (1.5 m) from the floor.
S
Close to or in a frequently used room, preferably on an inside partitioning wall.
S
On a section of wall without pipes or ductwork.
S
The Evolution Connex Control and Remote Room Sensors SHOULD NOT be
mounted:
Close to a window, on an outside wall, or next to a door leading to the outside.
S
Exposed to direct light or heat from a lamp, sun, fireplace, or other
S
temperature- - radiating objects which could cause a false reading.