5.3.

Indoor Evaporator Selection

If a furnace is installed with a variable capacity heat pump or an Evolution V heat
pump, a screen will appear to select the installed indoor evaporator coil. This
selection is used to adequately calculate the refrigerant charge required while in the
heat pump charging screens under the Heat Pump Checkout menu (See Pg. 54).
Select "other" for non- - Bryant evaporators.
5.4.

Electric Heater Selection

If the indoor equipment is a fan coil, the control will display "Searching for heater"
until one is found. If the electric heater is not self- - identifying, the select heater
screen will appear. Touch the appropriate heater size; then, touch SELECT.