Product Identification - Goodman GMV95 Technical Information Manual

40" 95% gas furnace units
Table of Contents

Advertisement

PRODUCT IDENTIFICATION

The model and manufacturing number are used for positive identification of component parts used in manufacturing.
Please use these numbers when requesting service or parts information.
G
Product Type
G: Goodman Brand
Supply Type
C: Counterflow/Horizontal
M: Upflow/Horizontal
Furnace Type
V: Variable Speed - 2 Stage
Model Family
95: 95% AFUE
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
2
M
V 95 045 3
Nominal Input
045:
45,000 Btuh
070:
70,000 Btuh
090:
90,000 Btuh
115:
115,000 Btuh
HIGH VOLTAGE!
Disconnect ALL power before servicing or installing this unit. Multiple
power sources may be present. Failure to do so may cause property
damage, personal injury or death.
Installation and repair of this unit should be performed ONLY by individu-
als meeting the requirements of an "entry level technician" as specified
by the Air Conditioning and Refrigeration Institute (ARI). Attempting to
install or repair this unit without such background may result in product
damage, personal injury or death.
Goodman will not be responsibile for any injury or property damage arising
from improper service or service procedures. If you install or perform
service on this unit, you assume responsibility for any personal injury or
property damage which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.
B X
Cabinet Width
B: 17 1/2"
C: 21"
D: 24 1/2"
Airflow Capability
3: 1200
4: 1600
5: 2000
A
Design Series
A: Initial Release
Additional Features
N: Natural Gas
X: Low NOx