BLOWER PERFORMANCE SPECIFICATIONS
GMV95 High (Single) Stage Cooling Speed Charts
GMV950453BX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
540
A
Normal
600
Plus (+)
660
Minus(-)
720
B
Normal
800
Plus (+)
880
Minus(-)
900
C
Normal
1000
Plus (+)
1100
Minus(-)
1080
D
Normal
1200
Plus (+)
1320
GMV95 Low Stage Cooling Speed Charts
GMV950453BX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
380*
A
Normal
390
Plus (+)
429
Minus(-)
468
B
Normal
520
Plus (+)
572
Minus(-)
585
C
Normal
650
Plus (+)
715
Minus(-)
702
D
Normal
780
Plus (+)
858
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed as
needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on rating
plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM minimum.
GMV950704CX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
540
A
Normal
600
Plus (+)
660
Minus(-)
720
B
Normal
800
Plus (+)
880
Minus(-)
990
C
Normal
1100
Plus (+)
1210
Minus(-)
1286
D
Normal
1429
Plus (+)
1572
GMV950704CX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
378*
A
Normal
390
Plus (+)
429
Minus(-)
468
B
Normal
520
Plus (+)
572
Minus(-)
644
C
Normal
715
Plus (+)
787
Minus(-)
836
D
Normal
929
Plus (+)
1022
GMV950905DX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
720
A
Normal
800
Plus (+)
880
Minus(-)
990
B
Normal
1100
Plus (+)
1210
Minus(-)
1260
C
Normal
1400
Plus (+)
1540
Minus(-)
1620
D
Normal
1800
Plus (+)
1980
GMV950905DX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
513*
A
Normal
520
Plus (+)
572
Minus(-)
644
B
Normal
715
Plus (+)
787
Minus(-)
819
C
Normal
910
Plus (+)
1001
Minus(-)
1053
D
Normal
1170
Plus (+)
1287
GMV951155DX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
720
A
Normal
800
Plus (+)
880
Minus(-)
990
B
Normal
1100
Plus (+)
1210
Minus(-)
1260
C
Normal
1400
Plus (+)
1540
Minus(-)
1620
D
Normal
1800
Plus (+)
1980
GMV951155DX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
514*
A
Normal
520
Plus (+)
572
Minus(-)
644
B
Normal
715
Plus (+)
787
Minus(-)
819
C
Normal
910
Plus (+)
1001
Minus(-)
1053
D
Normal
1170
Plus (+)
1287