Goodman CVC97 Series Technical Manual
Goodman CVC97 Series Technical Manual

Goodman CVC97 Series Technical Manual

97% gas furnace units

Advertisement

Quick Links

TECHNICAL MANU
TECHNICAL MANU AL
TECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANU
Refer to Service Manual RS6612009 for installation, operation, and troubleshooting information.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures performed by an unqualified person.
TM
*CVC97/*MVC97
97% Gas Furnace Units
Copyright ©2014 Goodman Manufacturing
AL
AL
AL
AL
Company, L.P.
RT6612031
September 2014

Advertisement

Table of Contents
loading

Summary of Contents for Goodman CVC97 Series

  • Page 1 • Models listed on page 3. RT6612031 This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does September 2014 not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person.
  • Page 2: Product Identification

    Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Installation and repair of this unit Goodman will not be responsible should be performed ONLY by in- WARNING WARNING...
  • Page 3 WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materi- Serious property damage, personal injury, reduced unit als or use gasoline or other flammable liquids or vapors performance and/or hazardous conditions may result in the vicinity of this appliance.
  • Page 4: Furnace Specifications

    FURNACE SPECIFICATIONS *MVM97 *MVM97 *MVM97 *MVM97 *MVM97 0603BNA 0803BNA 0804CNA 1005CNA 1205DNA Heating Data Hi gh Fi re Input¹ 60,000 80,000 80,000 100,000 120,000 Hi gh Fi re Output¹ 58,200 77,600 77,600 97,000 116,400 Low-Fi re Stea dy-Sta te Input¹ 30,000 40,000 40,000...
  • Page 5 FURNACE SPECIFICATIONS *CVM97 *CVM97 *CVM97 *CVM97 0603BNA 0803BNA 0804CNA 1005CNA Heating Data High Fi re Input¹ 60,000 80,000 80,000 100,000 High Fi re Output¹ 58,200 77,600 77,600 97,000 Low-Fi re Stea dy-Sta te Input¹ 30,000 40,000 40,000 50,000 Low-Fi re Stea dy-Sta te Output¹ 29,100 38,800 38,800...
  • Page 6: Product Dimensions

    PRODUCT DIMENSIONS DISCHARGE DISCHARG E 28 ¾ DIMB ¾ 6½ DISCHARG E 2¾ 6½ ¾ AIR INTAKE 2 ⅝ 1⅞ 2" PIPE 19½ CENTER DIMPL E VENT/FLUE PIPE LEFT SIDE FOR ALTERNATE ALTERNATE 2" PVC DRAIN TRAP AIR INTAKE PIP E VENT/FLU E ¾...
  • Page 7 PRODUCT DIMENSIONS TOP VIEW FRONT VIEW RIGHT SIDE VIEW 6½ 2⅝ 2½ 1⅝ 1⅞ 1⅜ 1 ⅞ ALTERNATE VENT/ FLUE LOCATION 1½ LOW VOLTAGE ELECTRICAL OUTLET LOW VOLTAGE ELECTRICAL OUTLET SIDE CUT-OU T SIDE CUT-OU T ALTERNATE GAS ALTERNATE SUPPLY LOCATION GAS SUPPLY LOCATIO N HIGH VOLTAG E...
  • Page 8: Blower Performance Specifications

    BLOWER PERFORMANCE SPECIFICATIONS *MVM970603BNA *MVM970603BNA Cooling Speed Heating Speed (@ .1" - .8" w.c. ESP) (@ .1" - .5" w.c. ESP; Rise Range: 20 - 50°F) High-Stage Low-Stage High-Stage Rise Adjust Adjust (°F) Minus 10% Minus 10% Normal Normal Plus 10% Plus 10% 1,048 Minus 10%...
  • Page 9 BLOWER PERFORMANCE SPECIFICATIONS *MVM971005CNA *MVM971005CNA Cooling Speed Heating Speed (@ .1" - .8" w.c. ESP) (@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F) High-Stage Low-Stage High-Stage Rise Adjust Adjust (°F) Minus 10% Minus 10% 1,636 Normal Normal 1,818 Plus 10% Plus 10%...
  • Page 10 BLOWER PERFORMANCE SPECIFICATIONS *CVM970603BNA *CVM970603BNA Cooling Speed Heating Speed (@ .1" - .8" w.c. ESP) (@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F) High-Stage Low-Stage High-Stage Rise Adjust Adjust (°F) Minus 10% Minus 10% Normal Normal Plus 10% Plus 10% 1,032 Minus 10%...
  • Page 11 BLOWER PERFORMANCE SPECIFICATIONS *CVM970804CNA *CVM970804CNA Cooling Speed Heating Speed (@ .1" - .8" w.c. ESP) (@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F) High-Stage Low-Stage High-Stage Rise Adjust Adjust (°F) Minus 10% Minus 10% 1,111 Normal Normal 1,234 Plus 10% Plus 10%...
  • Page 12: Wiring Diagrams

    WIRING DIAGRAMS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 115 VAC/1 Ø /60 POWERSUPPLY WITH OVERCURREN T ID BLOWERMODULATING PRESS URE PROTECTION SWITCH ASSEMB LY SUR FACE...