Page 1
Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does RT6612025r5 not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person.
Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible Installation and repair of this unit WARNING WARNING...
Page 3
WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materials or use gasoline or Serious property damage, personal injury, reduced unit other flammable liquids or vapors in the vicinity of this performance and/or hazardous conditions may result appliance.
PRODUCT DESIGN Notes: General Operation Models covered by this manual come with a new 4-wire com- 1. Installer must supply one or two PVC pipes: one for com- municating PCB. When paired with a compatible communi- bustion air (optional) and one for the flue outlet (required). cating indoor unit and a CTK0* communicating thermostat, Vent pipe must be either 2”...
Page 5
PRODUCT DESIGN High Altitude Derate High altitude kits are purchased according to the installa- When this furnace is installed at high altitude, the appropri- tion altitude and usage of either natural or propane gas. Refer ate High Altitude orifice kit must be installed. This is re- to the chart below for a tabular listing of appropriate altitude quired due to the natural reduction in the density of both the ranges and corresponding manufacturer’s high altitude Natu-...
COMPONENT IDENTIFICATION N OTICE H o ri z ont a l C onn ect i o ns- Lef t S i de H o ri z ont al C o n n ect i o ns- R i ght S i d e 0140F00 821 N O TIC E Thi s f i t t i n g i s s p ec i al l y d esi g n ed t o...
Page 9
PRODUCT DESIGN PRESSURE SWITCH TRIP POINTS AND USAGE CHART NEGATIVE PRESSURE NEGATIVE PRESSURE NEGATIVE PRESSURE NEGATIVE PRESSURE ID BLOWER ID BLOWER COIL COVER COIL COVER WITH FLUE WITH FLUE WITH FLUE WITH FLUE NOT FIRING FIRING NOT FIRING FIRING MODEL TYPICAL SEA LEVEL TYPICAL SEA LEVEL TYPICAL S EA LEVEL...
Page 11
PRODUCT DESIGN PRIMARY LIMIT Part Number 20162903 20162904 20162905 20162907 20162908 0130F001 05 Open Setting (°F) GMVC950453BX* AMVC950453BX* GMVC950704CX* AMVC950704CX* GMVC950905CX* AMVC950905CX* GMVC950905DX* AMVC950905DX* GMVC951155DX* AMVC951155DX* GCVC950714CX* ACVC950714CX* GCVC950915DX* ACVC950915DX* GCVC91155DX* ---- ---- ---- ---- ACVC951155DX* ROLLOUT LIMIT SWITCHES Part Number 10123512 1012 3517 10123518...
Page 12
PRODUCT DESIGN Thermostats: ComfortNet™ CTK0* Thermostat Kit Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty Upflow Filters Return air filters may be installated at the furnace side and/or bottom return openings.
Page 20
BLOWER PERFORMANCE SPECIFICATIONS GCVC951155DX Cooling/Heating Speed Charts GCVC91155DX* GCVC91155DX* ACVC951155DX* ACVC951155DX* Cooling Speeds He ating Speeds (@.1" -.8" w.c. ESP) (@.1" -.5" w.c. ESP; Rise Range: 40 - 70°F) High-Stage Low-Stage High-Stage Low-Stage Adjust Adjust Rise 1,093 Minus 10% Minus 10% 1,583 Minu s 5% Minus 5%...
Page 21
BLOWER PERFORMANCE SPECIFICATIONS Circulator Blower Speed Adjustment Switches Dip Switch Switch Bank Purpose Function Heating Off Delay 2 Stage Stat 2 Stage Stat Thermostat Setup 1 Stg Stat 5 min delay 1 Stg Stat auto delay Cooling Airflow Add 5% Minus 5% Trim Add 10%...
Page 22
BLOWER PERFORMANCE SPECIFICATIONS Ramping Profile Note: The multi-speed circulator blower also offers several custom ON/OFF ramping profiles. These profiles may be used to enhance cooling performance and increase comfort level. The ramping profiles are selected using DIP switches 5 and 6.
WIRING DIAGRAMS *CVC9/*MVC95_A* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
Page 24
ANSI Z21.20 AUTOMATIC IGNITION SYSTEM 24VAC 60Hz 0.8 A. MAX. BLOWER ASSEMBLY SCHEMATIC ACVC9/AMVC95/GCVC9/GMVC95_____X* MODEL FURNACES This schematic is for reference only. Not all wiring is as shown above, refer to the appropriate wiring diagram for the unit being serviced.
Page 25
SCHEMATICS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.