TECHNICAL INFORMATION MANUAL GMV95 40" 95% Gas Furnace Units GCV9 40" 90% Gas Furnace Units Models listed on page 2. • Refer to Service Manual RS6610004* for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual.
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. 95 045 3 B Product Type Design Series G: Goodman Brand A: Initial Release Additional Features Supply Type N: Natural Gas...
Page 3
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GMV950453BX* GMV950704CX* GMV950905DX* GMV951155DX* GCV90704CX* GCV90905DX* GCV91155DX* The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants WARNING WARNING...
PRODUCT DESIGN General Operation 3. Conversion kits for propane gas and high altitude natural and propane gas operation are available. See The GMV95 and GCV9 furnaces are equipped with an elec- tronic ignition device to light the burners and an induced draft High Altitude Derate chart for details.
Page 5
PRODUCT DESIGN High Altitude Derate When this furnace is installed at high altitude, the appropriate High Altitude orifice kit must be installed. This is required due to the natural reduction in the density of both the gas fuel and combustion air as altitude increases. The kit will provide the proper design certified input rate within the specified altitude range.
COMPONENT IDENTIFICATION Intell-Ignition Counterflow /Horizontal Upflow/Horizontal Two-Stage Gas Valve Coil Front Cover Pressure Tap Gas Line Entrance (Alternate) Coil Front Cover Drain Port Pressure Switch(es) Drain Line Penetrations Gas Manifold Drain Trap Combustion Air Intake Connection Blower Door Interlock Switch Hot Surface Igniter Inductor (Not All Models) Rollout Limit...
PRODUCT DIMENSIONS GMV95___XA DISCHARGE DISCHARGE INTAKE PIPE 2" PVC RIGHT SIDE 1 1/2 DRAIN LINE HOLES 1 5/8 UNFOLDED FLANGES UNFOLDED FLANGES FOLDED FLANGES FOLDED FLANGES RIGHT SIDE VIEW Cabinet Size GMV950453BX* 17-1/2 12-15/16 12-1/8 13-5/8 GMV950704CX* 19-1/2 15-15/16 17-1/2 GMV950905DX* 24-1/2 20-7/16...
Page 8
PRODUCT DIMENSIONS GCV9_____XA LEFT SIDE FRONTVIEW RIGHT SIDE VIEW VIEW 28 3/4 2 1/2 VENT/FLUE PIPE 20 1/4 (RETURN AIR) AIR INTAKE PIPE 2" PVC 2" PVC CONDENSATE DRAIN TRAP LOW VOLTAGE 1 3/4 ELECTRICAL HOLE w/ 3/4" PVC 1 3/4 DISCHARGE LOW VOLTAGE HIGH VOLTAGE...
Page 9
PRODUCT DESIGN PRESSURE SWITCH TRIP POINTS AND USAGE CHART NEGATIVE NEGATIVE NEGATIVE NEGATIVE PRESSURE PRESSURE PRESSURE PRESSURE ID BLOWER ID BLOWER COIL COVER COIL COVER WITH FLUE WITH FLUE WITH FLUE WITH FLUE NOT FIRING FIRING NOT FIRING FIRING MODEL TYPICAL SEA TYPICAL SEA TYPICAL SEA...
Page 11
PRODUCT DESIGN Coil Matches: ® A large array of Goodman brand coils are available for use with the GMV95 & GCV9 model furnaces, in either upflow or horizontal applications. These coils are available in both cased and uncased models, with or without a TXV expansion device.
Page 12
PRODUCT DESIGN Thermostats: The following 2-stage thermostats are recommended for use with GMV95 & GCV9 Furnace Models: THERMOSTATS Thermostat Mechanical / Digital CHT90-120 Cooling/Heating, Mechanical CH70TG Cooling/Heating, Digital, Non-programmable CHSATG Cooling/Heating, Mechanical Heating Only, Mechanical H20TWR Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards.
Page 20
BLOWER PERFORMANCE SPECIFICATIONS GMV95/GCV9 Circulator Blower Speed Adjustment Switches Note: There is a green LED adjacent to the integrated control module fuse which is used to verify airflow volume. The green CFM LED blinks once for each 100 CFM of airflow.
GMV95/GCV9 WIRING DIAGRAMS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 40 V A T R A N S - F O R M E R...
Page 25
SCHEMATICS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. LINE XFMR CIRC XFMR LINE PARK COOL HEAT SINGLE HEAT BLOWER ASSEMBLY SCHEMATIC GMV95/GCV9_____X* MODEL FURNACES This schematic is for reference only.
Page 26
SCHEMATICS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.