Heat & Glo 6000TRI-IPI Installer's Manual page 16

Table of Contents

Advertisement

V (FT.)
1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
NOTE: H + H
= 20' MAX. (6.2m)
1
V + V
+ H + H
1
V
1
V + V
(FT.)
1
1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
H +H
= 20' MAX. (6.2m)
1
V+V
+H +H
NOTE:
1
1
Figure 17. Venting with three 90° elbows
20
VENTING WITH THREE (3) 90° ELBOWS
H (FT.)
5' MAX. (1.52m)
10' MAX. (3.1m)
15' MAX. (4.65m)
20' MAX. (6.2m)
= 40' MAX. (12.4m)
1
H
1
H
1
H + H
(FT.)
1
5' MAX. (1.52m)
10' MAX. (3.1m)
15' MAX. (4.65m)
20' MAX. (6.2m)
= 40' MAX. (12.4m)
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05
V
1
H
V
H
V

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000tri-sp

Table of Contents