3. Match the amount of vertical you have in the sys-
tem with the chart to find the appropriate position
to set the Flue Restrictor (see Figure 9).
- CHART -
Top Vent
Top Vent
Vertical
NG
4'
1-1
Restrictor
8'
2-2
15'
3-3
20'
3-4
25'
3-4
30'
4-4
35'
4-4
40'
5-4
Figure 9
4. Center the Flue Restrictor on vent and secure in
place by using two self-tapping screws.
5. Reinstall the Exhaust Shield.
Figure 10
16
Rear Vent
Rear Vent
LP
NG
LP
No
No
No
Restrictor
Restrictor
No
1-2
1-1
Restrictor
3-2
2-2
1-2
3-3
3-3
2-3
3-3
3-3
2-3
3-4
3-4
3-3
3-4
3-4
3-3
4-4
4-4
3-4
1
2
3
4 5
SETTINGS
1
2
3
4 5
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05
HORIZONTAL VENTING
Kit No.
DVP-TRAP
H
45-DEGREE
ELBOW
NOTE: This model is tested and approved to use
45° elbows in corner installations. However, 90°
elbows will result in better performance. The
use of two 90
elbows in a corner installation
0
will affect space requirements (see Figure 2).
Figure 11. Corner Installation
H Max. Run
24" (610 mm)
90-DEGREE
ELBOWS