STRAIGHT UP
VERTICAL VENTING
V (FT.)
40' MAX. (12.4 M)
NOTE: On vertical venting
configurations over 10 feet
install the flue restrictor
(385-128) included in the
manual bag assembly. See
flue restrictor instructions.
Figure 6.
Straight Up Vertical Venting
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05
Flue Restrictor Instructions
1. Remove Exhaust Shield using a 1/4" nut driver by
removing the four screws securing it in place (see
Figure 7).
EXHAUST
SHIELD
FLUE
RESTRICTOR
Figure 7
2. Break the Flue Restrictor into two pieces. Do this
by bending the part back and forth until it breaks
(see Figure 8).
BREAK
HERE
Figure 8.
Flue Restrictor
15